Large hotel zoning

LargeHotel · geometric LOD study drop 5 · atlas inputs release 2.4.0 · BEMGen 99c0b0adcd44

Prototype
LargeHotel
Cells
24: 6 climate zones × 2 vintages × 2 orientations
Cells with a recommended zoning
24 of 24
Robust across orientations
12 of 12 cell pairs: Semantic merge + Stacked floor zone multiplier (7)
Reference zoning
No simplification + Stack
Reference zones
42
Most often recommended
Semantic merge + Stacked floor zone multiplier (13 of 24 cells)
Serial cost (R5)
not timed: the prototype is not among the timed cells of the serial pass
LOD recommendations 1.2.0, this prototype Downloadrelease 2.4.0 · SHA-256 7e2c0134667a1e7df368d832b26e7bf68954323acc19eb18651ffd3a7c40d53a

Robust across orientations

Robust across orientations in 12 of 12 cell pairs (0° and 45°).

Climate zoneVintageRobust zoningZonesHeating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Area change %CPU ratioWall ratioMemory ratioPer orientation

For each prototype, climate zone and vintage, the robust zoning is the coarsest (fewest modelled zones) that meets the threshold at every orientation of the cell pair, by the writer's own verdict on each zoning at each orientation, with at most the reference's zone count, as the writer bounds a recommendation (D-220); a duplicate never meets, as the writer lists it. Ties at the fewest zones go to a zoning both orientations recommend, else to the first in the study's zoning order (simplifier, join pieces, perimeter depth, stacker, IWHT, FHT); the tied zonings are named. The errors reported are the worse of the orientations' values for each metric, so the row is a bound, not a mean; the cost ratios are the medians over the timed sites of that zoning in the pair. Where both orientations recommend the same zoning it is the robust one. A pair where no zoning meets the threshold at both orientations says so and names each orientation's own recommendation; the per-orientation rows below stay the reading for one orientation. The cost ratios are the median over the timed sites of the robust zoning in the pair (in this drop one orientation at most is timed, so the ratio is that site's); not timed where none is. The rule and its limits.

Every zoning by cell

2A · 90.1-2007 · 0°

Reference 521cb45151096ace/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 0.4 and cooling 136.1 kWh/m²; peak heating 51.7 and cooling 305.5 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stack150.00-33.0-2.3160.82.833.02.3-15.2-2.5yes
Semantic merge + Stacked floor zone multiplier180.006.8-0.144.40.3-6.80.13.1-0.4yes
No simplification + Stacked floor zone multiplier210.009.5-0.151.40.2-9.50.13.5-0.1yes
Semantic merge + Stack330.00-2.3-0.112.30.22.30.1-0.4-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

2A · 90.1-2007 · 45°

Reference ca179bf1dbedb0b9/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 0.4 and cooling 126.5 kWh/m²; peak heating 18.6 and cooling 265.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stack150.00-41.8-2.2191.72.841.82.2-15.2-1.6yes
Semantic merge + Stacked floor zone multiplier180.005.4-0.135.40.3-5.40.110.2-0.1yes
No simplification + Stacked floor zone multiplier210.007.6-0.140.20.2-7.60.111.6-0.1yes
Semantic merge + Stack330.00-1.8-0.111.50.21.80.1-1.4-0.1yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

2A · 90.1-2019 · 0°

Reference 3ffa1db5992c723b/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 0.5 and cooling 127.4 kWh/m²; peak heating 43.4 and cooling 266.2 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stack150.00-36.8-2.6138.73.136.82.6-12.9-2.9yes
Semantic merge + Stacked floor zone multiplier180.009.5-0.048.40.3-9.50.03.5-0.4yes
No simplification + Stacked floor zone multiplier210.0011.90.054.50.2-11.9-0.03.9-0.1yes
Semantic merge + Stack330.00-2.0-0.110.10.22.00.1-0.4-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

2A · 90.1-2019 · 45°

Reference ad1f8d26708fdf56/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 0.5 and cooling 117.4 kWh/m²; peak heating 24.0 and cooling 241.9 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stack150.00-51.0-2.7175.53.451.02.7-22.0-1.8yes
Semantic merge + Stacked floor zone multiplier180.0012.6-0.153.90.3-12.60.16.5-0.1yes
No simplification + Stacked floor zone multiplier210.0014.8-0.058.70.2-14.80.07.0-0.1yes
Semantic merge + Stack330.00-1.9-0.010.40.21.90.0-0.6-0.0yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

2B · 90.1-2007 · 0°

Reference 31bbf4a226f87c01/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 1.3 and cooling 129.6 kWh/m²; peak heating 68.8 and cooling 343.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-20.0-2.864.63.420.02.8-9.8-2.1no
Conditioned merge + Stack150.00-29.5-2.885.53.429.52.8-12.8-2.1no
No simplification + Stacked floor zone multiplier210.0010.40.031.10.2-10.4-0.02.40.0no
Semantic merge + Stack330.00-2.3-0.17.30.22.30.1-0.3-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

2B · 90.1-2007 · 45°

Reference 3dbd59c71a78a599/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 1.0 and cooling 120.8 kWh/m²; peak heating 26.9 and cooling 294.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stack150.00-45.5-2.7122.83.445.52.7-18.5-1.5yes
Semantic merge + Stacked floor zone multiplier180.0011.2-0.137.10.4-11.20.14.0-0.1yes
No simplification + Stacked floor zone multiplier210.0013.4-0.039.40.2-13.40.04.8-0.1yes
Semantic merge + Stack330.00-2.2-0.18.00.22.20.1-0.8-0.1yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

2B · 90.1-2019 · 0°

Reference 6fd0347ca157086a/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 1.6 and cooling 122.9 kWh/m²; peak heating 58.0 and cooling 295.7 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-21.1-2.953.53.621.12.9-7.2-2.5no
Conditioned merge + Stack150.00-30.7-3.073.73.630.73.0-10.5-2.4no
No simplification + Stacked floor zone multiplier210.0011.80.130.80.3-11.8-0.12.5-0.0no
Semantic merge + Stack330.00-2.1-0.16.20.22.10.1-0.3-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

2B · 90.1-2019 · 45°

Reference 7284838646d1be24/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 1.3 and cooling 112.6 kWh/m²; peak heating 32.3 and cooling 266.9 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-34.2-3.280.84.034.23.2-2.3-1.6no
Conditioned merge + Stack150.00-47.1-3.2104.74.147.13.2-7.2-1.5no
Semantic merge + Stacked floor zone multiplier180.0013.50.032.50.4-13.5-0.01.9-0.1no
No simplification + Stacked floor zone multiplier210.0015.70.135.40.3-15.7-0.14.0-0.1no
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

3C · 90.1-2007 · 0°

Reference a77f321b47eaab15/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 1.0 and cooling 84.1 kWh/m²; peak heating 26.5 and cooling 235.4 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-10.4-4.952.95.710.44.9-4.2-1.7no
Conditioned merge + Stack150.00-29.9-5.167.75.829.95.1-11.2-1.1no
Semantic merge + Stacked floor zone multiplier180.0018.50.144.70.5-18.5-0.13.6-0.5no
No simplification + Stacked floor zone multiplier210.0021.40.248.20.5-21.4-0.24.0-0.1no
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

3C · 90.1-2007 · 45°

Reference fb90613dd1b263f7/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 0.9 and cooling 87.6 kWh/m²; peak heating 14.2 and cooling 200.8 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stack150.00-41.9-4.588.65.141.94.5-15.7-0.5yes
Semantic merge + Stacked floor zone multiplier180.0019.40.146.20.5-19.4-0.18.5-0.1yes
No simplification + Stacked floor zone multiplier210.0021.80.149.10.4-21.8-0.19.2-0.1yes
Semantic merge + Stack330.00-2.1-0.15.90.22.10.1-0.6-0.1yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

3C · 90.1-2019 · 0°

Reference 854fe2af02cf7eb6/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 1.7 and cooling 86.3 kWh/m²; peak heating 27.5 and cooling 210.6 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-17.5-4.744.65.617.54.7-1.8-3.9no
Conditioned merge + Stack150.00-35.0-5.057.95.835.05.0-8.1-2.6no
Semantic merge + Stacked floor zone multiplier180.0019.50.335.20.6-19.5-0.34.9-0.4no
No simplification + Stacked floor zone multiplier210.0021.70.438.00.6-21.7-0.45.1-0.0no
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

3C · 90.1-2019 · 45°

Reference 940bfedcf3f8af66/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 1.5 and cooling 83.5 kWh/m²; peak heating 16.9 and cooling 182.4 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-26.5-4.958.35.926.54.9-2.0-5.0no
Conditioned merge + Stack150.00-47.0-5.274.76.147.05.2-11.0-3.8no
Semantic merge + Stacked floor zone multiplier180.0022.10.335.60.6-22.1-0.37.50.0no
No simplification + Stacked floor zone multiplier210.0023.80.337.80.6-23.8-0.38.60.1no
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

4A · 90.1-2007 · 0°

Reference 6bbe9d71d72d0309/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 8.6 and cooling 94.5 kWh/m²; peak heating 142.4 and cooling 307.3 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-11.9-5.526.37.011.95.5-11.0-2.5no
Conditioned merge + Stack150.00-17.1-5.833.07.317.15.8-12.4-2.5no
No simplification + Stacked floor zone multiplier210.004.60.27.50.5-4.6-0.21.1-0.0yes
Semantic merge + Stack330.00-0.3-0.11.30.20.30.1-0.4-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

4A · 90.1-2007 · 45°

Reference a6a47e98c88a5c5b/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 5.7 and cooling 87.8 kWh/m²; peak heating 87.7 and cooling 250.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-14.9-5.433.26.914.95.4-19.0-1.5no
Conditioned merge + Stack150.00-22.7-5.742.17.422.75.7-21.0-1.4no
No simplification + Stacked floor zone multiplier210.006.70.310.60.5-6.7-0.31.6-0.1yes
Semantic merge + Stack330.00-0.5-0.11.60.20.50.1-0.5-0.1yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

4A · 90.1-2019 · 0°

Reference 2b326eabf7ffac60/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 9.5 and cooling 94.8 kWh/m²; peak heating 143.6 and cooling 271.4 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stack150.00-14.7-5.525.26.814.75.5-9.9-2.7no
Semantic merge + Stacked floor zone multiplier180.004.60.37.20.6-4.6-0.30.5-0.4yes
No simplification + Stacked floor zone multiplier210.004.90.47.50.6-4.9-0.41.0-0.0yes
Semantic merge + Stack330.00-0.3-0.11.10.20.30.1-0.5-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

4A · 90.1-2019 · 45°

Reference bed8374038e71d0d/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 8.1 and cooling 85.0 kWh/m²; peak heating 130.0 and cooling 226.5 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-12.3-5.724.07.512.35.7-14.9-1.8no
Conditioned merge + Stack150.00-18.6-6.230.88.018.66.2-16.4-1.7no
No simplification + Stacked floor zone multiplier210.005.80.48.50.6-5.8-0.41.1-0.2yes
Semantic merge + Stack330.00-0.3-0.11.10.20.30.1-0.3-0.0yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

5A · 90.1-2007 · 0°

Reference 2ae1e502ca5dfa92/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 15.8 and cooling 78.9 kWh/m²; peak heating 160.7 and cooling 296.7 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-12.5-8.724.011.412.58.7-7.2-2.5no
Conditioned merge + Stack150.00-16.0-9.128.211.816.09.1-7.8-2.4no
No simplification + Stacked floor zone multiplier210.003.20.34.70.6-3.2-0.30.8-0.1yes
Semantic merge + Stack330.00-0.2-0.10.80.20.20.1-0.1-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

5A · 90.1-2007 · 45°

Reference 68ae1c66f67c3bb2/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 9.5 and cooling 76.9 kWh/m²; peak heating 109.5 and cooling 236.9 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-15.4-7.530.19.915.47.5-12.2-1.7no
Conditioned merge + Stack150.00-21.0-8.036.610.521.08.0-13.7-1.6no
No simplification + Stacked floor zone multiplier210.005.00.47.20.7-5.0-0.41.3-0.1yes
Semantic merge + Stack330.00-0.3-0.11.10.20.30.1-0.5-0.1yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

5A · 90.1-2019 · 0°

Reference 676a64b6997e8eef/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 16.1 and cooling 83.3 kWh/m²; peak heating 142.4 and cooling 268.4 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-10.1-7.418.59.510.17.4-9.9-2.7no
Conditioned merge + Stack150.00-14.0-8.023.010.114.08.0-11.2-2.7no
No simplification + Stacked floor zone multiplier210.003.50.55.00.7-3.5-0.51.1-0.1yes
Semantic merge + Stack330.00-0.2-0.10.70.20.20.1-0.4-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

5A · 90.1-2019 · 45°

Reference 744bccbb5c1cab5b/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 13.0 and cooling 76.6 kWh/m²; peak heating 150.5 and cooling 215.8 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-12.2-7.621.610.012.27.6-14.3-2.2no
Conditioned merge + Stack150.00-17.0-8.326.910.617.08.3-15.5-2.1no
No simplification + Stacked floor zone multiplier210.004.30.65.80.8-4.3-0.60.9-0.1yes
Semantic merge + Stack330.00-0.2-0.10.80.20.20.1-0.4-0.0yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

7A · 90.1-2007 · 0°

Reference 9896f70971bcf6d6/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 24.5 and cooling 76.6 kWh/m²; peak heating 207.7 and cooling 319.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-14.2-11.125.014.814.211.1-5.1-2.5no
Conditioned merge + Stack150.00-16.3-11.427.315.216.311.4-5.4-2.5no
No simplification + Stacked floor zone multiplier210.002.00.42.90.6-2.0-0.40.5-0.0yes
Semantic merge + Stack330.00-0.2-0.10.70.30.20.1-0.1-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

7A · 90.1-2007 · 45°

Reference 1f852c1f217ffac7/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 16.1 and cooling 70.9 kWh/m²; peak heating 166.1 and cooling 240.6 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-18.9-10.833.114.518.910.8-14.2-1.4no
Conditioned merge + Stack150.00-22.1-11.236.615.022.111.2-15.0-1.4no
No simplification + Stacked floor zone multiplier210.002.90.44.10.7-2.9-0.40.7-0.1yes
Semantic merge + Stack330.00-0.2-0.10.80.30.20.1-0.2-0.0yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

7A · 90.1-2019 · 0°

Reference 2aaa56b818338be3/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 23.8 and cooling 80.4 kWh/m²; peak heating 170.5 and cooling 280.4 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-11.7-9.420.312.311.79.4-9.5-2.9no
Conditioned merge + Stack150.00-14.4-10.023.412.914.410.0-10.6-2.8no
No simplification + Stacked floor zone multiplier210.002.50.53.40.7-2.5-0.50.8-0.0yes
Semantic merge + Stack330.00-0.1-0.10.70.20.10.1-0.3-0.3yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

7A · 90.1-2019 · 45°

Reference f856fcca02c21118/R: No simplification + Stack, 42 zones, 9,366 m² conditioned; annual sensible heating 20.8 and cooling 72.4 kWh/m²; peak heating 178.7 and cooling 218.5 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Stacked floor zone multiplier60.00-13.9-10.323.313.413.910.3-11.8-1.8no
Conditioned merge + Stack150.00-17.0-11.026.614.217.011.0-12.7-1.7no
No simplification + Stacked floor zone multiplier210.002.80.63.60.8-2.8-0.60.8-0.2yes
Semantic merge + Stack330.00-0.1-0.10.60.20.10.1-0.10.0yes
18 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Conditioned merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Conditioned merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone building: the zoning does not support the prototype's multiplied rooms
  • No simplification + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 3 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stack: the zoning does not support the prototype's multiplied rooms
  • Perimeter core 4.57 m + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Semantic merge + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone building: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Single zone per floor type: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stack: the zoning does not support the prototype's multiplied rooms
  • Single zone per floor + Stacked floor zone multiplier: the zoning does not support the prototype's multiplied rooms

Atlas programs

The atlas programs each program key of the prototype takes, as the suite's saved inputs name them (release 2.4.0 IDs); the prototype's geometry and glazing are BEMGen's DOE record. Method and caveats.