Medium office zoning

MediumOffice · geometric LOD study drop 5 · atlas inputs release 2.4.0 · BEMGen 99c0b0adcd44

Prototype
MediumOffice
Cells
24: 6 climate zones × 2 vintages × 2 orientations
Cells with a recommended zoning
24 of 24
Robust across orientations
12 of 12 cell pairs: Perimeter core 3 m + Stack (7)
Reference zoning
No simplification + Stack
Reference zones
65
Most often recommended
Perimeter core 4.57 m + Stack (16 of 24 cells)
Serial cost (R5)
not timed: the prototype is not among the timed cells of the serial pass
LOD recommendations 1.2.0, this prototype Downloadrelease 2.4.0 · SHA-256 9db5f699f6f9d58d29f041652bcb92941ba9f0bcacbfd1047c1af28c80871f1d

Robust across orientations

Robust across orientations in 12 of 12 cell pairs (0° and 45°).

Climate zoneVintageRobust zoningZonesHeating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Area change %CPU ratioWall ratioMemory ratioPer orientation

For each prototype, climate zone and vintage, the robust zoning is the coarsest (fewest modelled zones) that meets the threshold at every orientation of the cell pair, by the writer's own verdict on each zoning at each orientation, with at most the reference's zone count, as the writer bounds a recommendation (D-220); a duplicate never meets, as the writer lists it. Ties at the fewest zones go to a zoning both orientations recommend, else to the first in the study's zoning order (simplifier, join pieces, perimeter depth, stacker, IWHT, FHT); the tied zonings are named. The errors reported are the worse of the orientations' values for each metric, so the row is a bound, not a mean; the cost ratios are the medians over the timed sites of that zoning in the pair. Where both orientations recommend the same zoning it is the robust one. A pair where no zoning meets the threshold at both orientations says so and names each orientation's own recommendation; the per-orientation rows below stay the reading for one orientation. The cost ratios are the median over the timed sites of the robust zoning in the pair (in this drop one orientation at most is timed, so the ratio is that site's); not timed where none is. The rule and its limits.

Every zoning by cell

2A · 90.1-2007 · 0°

Reference 74ec6c67b5da6c81/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.2 and cooling 94.1 kWh/m²; peak heating 62.4 and cooling 167.9 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-46.02.4478.012.546.0-2.4-11.37.5yes
Conditioned merge + Stacked floor zone multiplier30.0036.62.8660.312.5-36.6-2.832.78.9yes
Semantic merge + Single zone per floor type30.00-45.92.4477.912.545.9-2.4-11.27.5yes
Perimeter core 3 m + Stack150.0067.40.5577.02.2-67.4-0.5-3.80.1yes
Perimeter core 3 m + Stacked floor zone multiplier150.0093.70.7749.12.6-93.7-0.70.51.0yes
Perimeter core 4.57 m + Stack150.00-8.00.0144.81.28.0-0.0-8.5-0.2yes
Perimeter core 4.57 m + Stacked floor zone multiplier150.0019.70.2209.21.4-19.7-0.2-2.70.7yes
Semantic merge + Stack600.00-3.4-0.053.60.23.40.0-0.0-0.1yes
Semantic merge + Stacked floor zone multiplier600.0027.50.1260.41.2-27.5-0.17.50.8yes
No simplification + Stacked floor zone multiplier650.0031.70.2291.21.3-31.7-0.27.50.9yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2A · 90.1-2007 · 45°

Reference d502c2ae9025f2a9/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.2 and cooling 95.8 kWh/m²; peak heating 64.4 and cooling 171.7 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-46.32.8450.712.946.3-2.8-9.87.9yes
Conditioned merge + Stacked floor zone multiplier30.0031.33.2618.812.9-31.3-3.232.59.2yes
Semantic merge + Single zone per floor type30.00-46.32.8450.612.946.3-2.8-9.87.9yes
Perimeter core 3 m + Stack150.0054.30.4490.22.1-54.3-0.4-4.40.2yes
Perimeter core 3 m + Stacked floor zone multiplier150.0078.10.6640.12.5-78.1-0.6-0.41.1yes
Perimeter core 4.57 m + Stack150.00-14.6-0.0154.01.114.60.0-8.0-0.2yes
Perimeter core 4.57 m + Stacked floor zone multiplier150.0011.20.2157.61.4-11.2-0.2-2.40.7yes
Semantic merge + Stack600.00-3.5-0.046.60.13.50.00.3-0.0yes
Semantic merge + Stacked floor zone multiplier600.0025.30.1235.51.3-25.3-0.17.30.8yes
No simplification + Stacked floor zone multiplier650.0027.80.2247.41.3-27.8-0.27.10.9yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2A · 90.1-2019 · 0°

Reference 0a5d401c861caf80/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.0 and cooling 73.3 kWh/m²; peak heating 16.5 and cooling 170.1 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00–2.4–13.7–-2.412.99.6yes
Conditioned merge + Stacked floor zone multiplier30.00–2.7–12.9–-2.7155.57.5yes
Semantic merge + Single zone per floor type30.00–2.3–13.7–-2.313.09.6yes
Perimeter core 3 m + Stack150.00–0.1–2.2–-0.128.6-1.0yes
Perimeter core 3 m + Stacked floor zone multiplier150.00–0.3–2.7–-0.344.3-1.9yes
Perimeter core 4.57 m + Stack150.00–0.0–1.3–-0.0-9.1-0.2yes
Perimeter core 4.57 m + Stacked floor zone multiplier150.00–0.2–1.5–-0.217.7-1.0yes
Semantic merge + Stack600.00–-0.0–0.3–0.0-1.0-0.0yes
Semantic merge + Stacked floor zone multiplier600.00–0.1–1.1–-0.134.4-0.8yes
No simplification + Stacked floor zone multiplier650.00–0.2–1.2–-0.235.2-0.7yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2A · 90.1-2019 · 45°

Reference 6b8793b19df2a377/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.0 and cooling 74.6 kWh/m²; peak heating 18.0 and cooling 179.5 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00–2.7–14.3–-2.78.410.0yes
Conditioned merge + Stacked floor zone multiplier30.00–3.0–13.4–-3.0143.18.1yes
Semantic merge + Single zone per floor type30.00–2.7–14.2–-2.78.410.0yes
Perimeter core 3 m + Stack150.00–0.1–2.2–-0.126.1-1.1yes
Perimeter core 3 m + Stacked floor zone multiplier150.00–0.2–2.8–-0.239.7-1.9yes
Perimeter core 4.57 m + Stack150.00–-0.0–1.2–0.0-10.0-0.2yes
Perimeter core 4.57 m + Stacked floor zone multiplier150.00–0.1–1.5–-0.114.8-1.0yes
Semantic merge + Stack600.00–-0.0–0.2–0.0-0.4-0.1yes
Semantic merge + Stacked floor zone multiplier600.00–0.2–1.2–-0.232.8-0.8yes
No simplification + Stacked floor zone multiplier650.00–0.2–1.2–-0.232.8-0.7yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2007 · 0°

Reference 63572866fa6fa4a1/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 1.0 and cooling 88.2 kWh/m²; peak heating 78.3 and cooling 186.9 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-30.50.3241.919.530.5-0.366.59.2yes
Conditioned merge + Stacked floor zone multiplier30.0016.61.1273.718.8-16.6-1.168.110.3yes
Semantic merge + Single zone per floor type30.00-30.40.3242.619.530.4-0.367.09.2yes
Perimeter core 3 m + Stack150.0027.10.8166.43.5-27.1-0.8-3.10.0yes
Perimeter core 3 m + Stacked floor zone multiplier150.0044.21.3207.23.9-44.2-1.35.60.8yes
Perimeter core 4.57 m + Stack150.00-14.5-0.3102.82.314.50.3-11.9-0.2yes
Perimeter core 4.57 m + Stacked floor zone multiplier150.003.80.272.72.2-3.8-0.26.90.6yes
Semantic merge + Stack600.00-3.6-0.122.90.43.60.1-1.3-0.1yes
Semantic merge + Stacked floor zone multiplier600.0013.80.395.91.5-13.8-0.315.50.6yes
No simplification + Stacked floor zone multiplier650.0017.50.4109.61.6-17.5-0.416.80.7yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2007 · 45°

Reference 692f7a3ec1b0d8f3/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 1.1 and cooling 90.2 kWh/m²; peak heating 83.0 and cooling 199.5 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-16.21.4425.022.616.2-1.4116.014.4no
Semantic merge + Single zone building10.00-16.11.4425.822.616.1-1.4116.414.4no
Conditioned merge + Single zone per floor type30.00-25.01.0241.419.725.0-1.074.19.8no
Conditioned merge + Stacked floor zone multiplier30.0018.11.7296.719.1-18.1-1.774.810.9no
Semantic merge + Single zone per floor type30.00-24.91.0242.219.724.9-1.074.69.7no
Perimeter core 3 m + Stack150.0021.80.7147.23.2-21.8-0.7-8.50.0no
Perimeter core 3 m + Stacked floor zone multiplier150.0038.21.2187.33.8-38.2-1.23.30.8no
Perimeter core 4.57 m + Stack150.00-16.6-0.392.12.116.60.3-16.1-0.2no
Perimeter core 4.57 m + Stacked floor zone multiplier150.000.90.266.72.1-0.9-0.26.90.5no
Semantic merge + Stacked floor zone multiplier600.0014.40.496.71.5-14.4-0.415.40.6no
No simplification + Stacked floor zone multiplier650.0016.50.4102.61.6-16.5-0.415.70.7no
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2019 · 0°

Reference f45ec3d5871ce293/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.2 and cooling 68.9 kWh/m²; peak heating 31.9 and cooling 187.1 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-42.10.8407.720.342.1-0.846.49.7yes
Conditioned merge + Stacked floor zone multiplier30.00123.01.61,355.518.5-123.0-1.669.07.7yes
Semantic merge + Single zone per floor type30.00-41.90.7408.720.341.9-0.747.39.7yes
Perimeter core 3 m + Stack150.0035.00.3295.53.5-35.0-0.36.4-1.0yes
Perimeter core 3 m + Stacked floor zone multiplier150.0091.40.8573.93.9-91.4-0.823.1-2.4yes
Perimeter core 4.57 m + Stack150.00-21.4-0.2232.52.721.40.2-17.1-0.3yes
Perimeter core 4.57 m + Stacked floor zone multiplier150.0043.30.4328.92.5-43.3-0.418.6-1.6yes
Semantic merge + Stack600.00-11.3-0.192.60.611.30.1-1.5-0.1yes
Semantic merge + Stacked floor zone multiplier600.0058.50.4440.51.7-58.5-0.429.6-1.1yes
No simplification + Stacked floor zone multiplier650.0071.80.5511.71.8-71.8-0.534.2-1.0yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2019 · 45°

Reference 18b483e3337a52b1/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.2 and cooling 70.5 kWh/m²; peak heating 32.7 and cooling 197.7 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-37.41.4386.020.737.4-1.471.210.1yes
Conditioned merge + Stacked floor zone multiplier30.00116.12.21,230.118.9-116.1-2.274.98.2yes
Semantic merge + Single zone per floor type30.00-37.31.3387.920.637.3-1.372.310.1yes
Perimeter core 3 m + Stack150.0019.40.1217.63.1-19.4-0.15.5-1.1yes
Perimeter core 3 m + Stacked floor zone multiplier150.0070.00.7474.33.9-70.0-0.722.9-2.2yes
Perimeter core 4.57 m + Stack150.00-29.1-0.2210.72.329.10.2-15.7-0.3yes
Perimeter core 4.57 m + Stacked floor zone multiplier150.0028.90.3277.42.4-28.9-0.325.5-1.5yes
Semantic merge + Stack600.00-7.4-0.152.50.37.40.1-0.8-0.2yes
Semantic merge + Stacked floor zone multiplier600.0054.00.4399.81.8-54.0-0.432.7-0.9yes
No simplification + Stacked floor zone multiplier650.0061.40.5437.01.9-61.4-0.534.5-0.8yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2007 · 0°

Reference fd8ba3653f479429/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.4 and cooling 40.0 kWh/m²; peak heating 68.1 and cooling 119.2 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-30.6-28.4569.641.630.628.465.78.5no
Semantic merge + Single zone building10.00-29.9-28.7573.641.829.928.766.48.3no
Conditioned merge + Single zone per floor type30.00-38.0-30.0291.640.738.030.022.41.7no
Conditioned merge + Stacked floor zone multiplier30.0077.4-27.5741.736.1-77.427.568.23.1no
Semantic merge + Single zone per floor type30.00-37.8-30.3291.940.937.830.322.81.6no
Semantic merge + Stack600.00-5.2-0.134.60.75.20.1-0.6-0.1yes
Semantic merge + Stacked floor zone multiplier600.0030.61.1193.42.5-30.6-1.120.90.8yes
No simplification + Stacked floor zone multiplier650.0035.61.3212.42.7-35.6-1.321.50.9yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2007 · 45°

Reference 443812de5224681a/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.5 and cooling 40.8 kWh/m²; peak heating 69.4 and cooling 125.5 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-23.1-26.9590.639.723.126.972.58.2no
Semantic merge + Single zone building10.00-22.4-27.2595.539.922.427.273.18.1no
Conditioned merge + Single zone per floor type30.00-32.3-28.4286.938.932.328.427.92.3no
Conditioned merge + Stacked floor zone multiplier30.0076.7-26.0746.134.6-76.726.068.63.5no
Semantic merge + Single zone per floor type30.00-32.0-28.6288.539.132.028.628.32.2no
Semantic merge + Stack600.00-5.0-0.125.10.55.00.10.0-0.0yes
Semantic merge + Stacked floor zone multiplier600.0029.51.2192.22.6-29.5-1.221.60.8yes
No simplification + Stacked floor zone multiplier650.0033.21.2203.22.7-33.2-1.221.80.8yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2019 · 0°

Reference 8d6bdec8cadd987d/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.1 and cooling 31.9 kWh/m²; peak heating 31.7 and cooling 109.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-40.3-23.21,049.542.840.323.293.16.5no
Semantic merge + Single zone building10.00-39.0-23.51,061.343.239.023.594.66.2no
Conditioned merge + Single zone per floor type30.00-39.3-24.3527.641.439.324.320.4-1.5no
Conditioned merge + Stacked floor zone multiplier30.00253.5-21.92,776.336.4-253.521.9102.50.3no
Semantic merge + Single zone per floor type30.00-38.7-24.6528.941.838.724.620.8-1.8no
Semantic merge + Stack600.00-13.9-0.2135.10.913.90.2-3.60.1yes
Semantic merge + Stacked floor zone multiplier600.00105.51.3817.83.3-105.5-1.339.10.5yes
No simplification + Stacked floor zone multiplier650.00125.61.5913.73.6-125.6-1.541.30.3yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2019 · 45°

Reference d932eaf678ee5e05/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 0.1 and cooling 32.7 kWh/m²; peak heating 31.4 and cooling 114.8 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-31.5-21.51,099.540.331.521.5119.76.3no
Semantic merge + Single zone building10.00-30.3-21.81,117.040.730.321.8121.26.0no
Conditioned merge + Single zone per floor type30.00-35.9-22.6539.439.235.922.634.0-1.0no
Conditioned merge + Stacked floor zone multiplier30.00226.4-20.32,382.234.4-226.420.3108.90.7no
Semantic merge + Single zone per floor type30.00-35.3-22.9544.739.635.322.934.5-1.2no
Semantic merge + Stack600.00-11.5-0.180.20.511.50.11.90.0yes
Semantic merge + Stacked floor zone multiplier600.0086.21.4670.03.4-86.2-1.442.10.3yes
No simplification + Stacked floor zone multiplier650.0097.11.5716.93.6-97.1-1.543.90.3yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2007 · 0°

Reference 112489516afaf6b4/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 13.5 and cooling 47.9 kWh/m²; peak heating 363.8 and cooling 171.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0038.8-3.8168.723.1-38.83.828.211.3no
Semantic merge + Single zone building10.0039.0-4.0169.323.1-39.04.028.211.2no
Conditioned merge + Single zone per floor type30.0039.1-4.4134.119.5-39.14.418.64.7no
Conditioned merge + Stacked floor zone multiplier30.0041.2-3.6133.217.9-41.23.615.65.9no
Semantic merge + Single zone per floor type30.0039.4-4.6134.719.6-39.44.618.74.5no
Semantic merge + Stack600.00-0.5-0.12.60.50.50.1-0.3-0.1yes
Semantic merge + Stacked floor zone multiplier600.002.71.017.13.5-2.7-1.0-2.10.7yes
No simplification + Stacked floor zone multiplier650.003.11.117.43.8-3.1-1.1-1.90.7yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2007 · 45°

Reference bd584ce06055d1ea/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 13.8 and cooling 48.9 kWh/m²; peak heating 364.4 and cooling 175.6 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0040.5-2.8166.522.1-40.52.828.011.2no
Semantic merge + Single zone building10.0040.7-3.0167.122.1-40.73.028.011.1no
Conditioned merge + Single zone per floor type30.0040.9-3.4133.518.7-40.93.418.24.8no
Conditioned merge + Stacked floor zone multiplier30.0042.9-2.7132.217.1-42.92.715.55.9no
Semantic merge + Single zone per floor type30.0041.2-3.6134.018.7-41.23.618.34.7no
Semantic merge + Stack600.00-0.2-0.11.60.20.20.1-0.9-0.0yes
Semantic merge + Stacked floor zone multiplier600.002.61.016.63.6-2.6-1.0-2.10.6yes
No simplification + Stacked floor zone multiplier650.002.81.016.73.7-2.8-1.0-1.90.7yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2019 · 0°

Reference 564e3125a6a4c8c1/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 12.0 and cooling 37.4 kWh/m²; peak heating 258.4 and cooling 181.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0026.6-2.3132.123.8-26.62.317.67.0no
Semantic merge + Single zone building10.0026.8-2.5132.623.7-26.82.517.67.0no
Conditioned merge + Single zone per floor type30.0027.4-3.0102.022.3-27.43.014.38.0no
Conditioned merge + Stacked floor zone multiplier30.0028.3-2.3102.420.5-28.32.310.36.8no
Semantic merge + Single zone per floor type30.0027.6-3.2102.422.3-27.63.214.37.9no
Perimeter core 3 m + Stack150.00-7.1-1.130.56.37.11.1-5.9-0.3no
Perimeter core 3 m + Stacked floor zone multiplier150.00-5.5-0.134.06.75.50.1-7.7-0.6no
Semantic merge + Stack600.00-0.5-0.23.60.80.50.2-0.2-0.0yes
Semantic merge + Stacked floor zone multiplier600.001.00.716.72.9-1.0-0.7-1.9-0.5yes
No simplification + Stacked floor zone multiplier650.001.60.917.13.2-1.6-0.9-1.6-0.5yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2019 · 45°

Reference 9a61ed4d33f92bb8/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 12.3 and cooling 38.3 kWh/m²; peak heating 258.9 and cooling 182.5 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0028.8-1.2130.522.8-28.81.217.46.6no
Semantic merge + Single zone building10.0029.1-1.4131.022.7-29.11.417.46.5no
Conditioned merge + Single zone per floor type30.0029.6-1.9102.221.8-29.61.914.28.2no
Conditioned merge + Stacked floor zone multiplier30.0030.6-1.2102.519.8-30.61.210.36.9no
Semantic merge + Single zone per floor type30.0029.8-2.1102.621.7-29.82.114.38.1no
Perimeter core 3 m + Stacked floor zone multiplier150.00-5.3-0.233.26.55.30.2-7.7-0.5no
Semantic merge + Stack600.00-0.3-0.12.40.30.30.1-0.2-0.0yes
Semantic merge + Stacked floor zone multiplier600.001.20.716.53.0-1.2-0.7-1.8-0.5yes
No simplification + Stacked floor zone multiplier650.001.50.816.73.2-1.5-0.8-1.6-0.5yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2007 · 0°

Reference e2da842cf2dd63d4/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 28.8 and cooling 32.3 kWh/m²; peak heating 469.3 and cooling 163.8 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0031.8-7.196.628.8-31.87.111.59.4no
Semantic merge + Single zone building10.0032.0-7.496.928.9-32.07.411.59.3no
Conditioned merge + Single zone per floor type30.0031.8-8.477.925.8-31.88.48.73.3no
Conditioned merge + Stacked floor zone multiplier30.0032.8-7.176.822.9-32.87.17.54.9no
Semantic merge + Single zone per floor type30.0032.0-8.778.226.0-32.08.78.83.3no
Semantic merge + Stack600.00-0.1-0.11.00.70.10.1-0.2-0.1yes
Semantic merge + Stacked floor zone multiplier600.001.11.410.25.0-1.1-1.4-2.70.9yes
No simplification + Stacked floor zone multiplier650.001.21.610.25.3-1.2-1.6-2.01.0yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2007 · 45°

Reference c403558abebd0265/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 29.0 and cooling 33.6 kWh/m²; peak heating 470.2 and cooling 167.3 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0032.1-5.895.927.0-32.15.811.69.1no
Semantic merge + Single zone building10.0032.3-6.196.227.1-32.36.111.69.0no
Conditioned merge + Single zone per floor type30.0032.2-7.077.824.0-32.27.08.83.6no
Conditioned merge + Stacked floor zone multiplier30.0033.2-5.876.621.3-33.25.87.65.1no
Semantic merge + Single zone per floor type30.0032.4-7.378.224.2-32.47.38.83.5no
Semantic merge + Stack600.00-0.1-0.10.50.30.10.1-0.2-0.0yes
Semantic merge + Stacked floor zone multiplier600.001.11.410.15.1-1.1-1.4-2.71.0yes
No simplification + Stacked floor zone multiplier650.001.21.410.15.2-1.2-1.4-2.01.0yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2019 · 0°

Reference d6f207965a9fc09c/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 24.6 and cooling 26.1 kWh/m²; peak heating 336.2 and cooling 158.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0022.8-5.378.430.9-22.85.39.58.7no
Semantic merge + Single zone building10.0023.0-5.678.731.0-23.05.69.68.5no
Conditioned merge + Single zone per floor type30.0023.2-6.459.928.6-23.26.48.36.3no
Conditioned merge + Stacked floor zone multiplier30.0024.0-5.360.025.8-24.05.36.05.4no
Semantic merge + Single zone per floor type30.0023.4-6.860.328.7-23.46.88.46.1no
Semantic merge + Stack600.00-0.2-0.21.91.20.20.2-0.20.1yes
Semantic merge + Stacked floor zone multiplier600.000.60.910.33.9-0.6-0.9-2.1-0.3yes
No simplification + Stacked floor zone multiplier650.000.81.110.34.4-0.8-1.1-1.9-0.4yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2019 · 45°

Reference 26ad72f23cb59751/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 24.8 and cooling 27.2 kWh/m²; peak heating 337.3 and cooling 161.5 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0023.5-3.777.728.8-23.53.79.39.3no
Semantic merge + Single zone building10.0023.7-4.178.128.8-23.74.19.49.1no
Conditioned merge + Single zone per floor type30.0023.9-4.960.026.8-23.94.98.37.2no
Conditioned merge + Stacked floor zone multiplier30.0024.5-3.959.723.9-24.53.96.06.1no
Semantic merge + Single zone per floor type30.0024.1-5.260.426.8-24.15.28.37.0no
Semantic merge + Stack600.00-0.1-0.12.20.40.10.1-0.2-0.0yes
Semantic merge + Stacked floor zone multiplier600.000.70.910.14.2-0.7-0.9-2.1-0.4yes
No simplification + Stacked floor zone multiplier650.000.71.010.04.4-0.7-1.0-1.9-0.4yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2007 · 0°

Reference 1a954eb9a01a5bc8/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 40.1 and cooling 33.9 kWh/m²; peak heating 536.5 and cooling 172.7 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0030.3-8.584.931.2-30.38.57.38.5no
Semantic merge + Single zone building10.0030.5-8.985.331.3-30.58.97.38.3no
Conditioned merge + Single zone per floor type30.0030.3-9.869.427.6-30.39.88.24.2no
Conditioned merge + Stacked floor zone multiplier30.0031.0-8.367.624.5-31.08.36.65.6no
Semantic merge + Single zone per floor type30.0030.5-10.169.827.9-30.510.18.24.0no
Semantic merge + Stack600.00-0.1-0.21.71.00.10.2-0.3-0.1yes
Semantic merge + Stacked floor zone multiplier600.001.21.710.85.7-1.2-1.7-2.10.9yes
No simplification + Stacked floor zone multiplier650.001.41.910.86.2-1.4-1.9-1.91.1yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2007 · 45°

Reference 6465f3d5434f0df4/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 40.6 and cooling 35.2 kWh/m²; peak heating 537.2 and cooling 183.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0030.7-7.183.729.3-30.77.17.28.0no
Semantic merge + Single zone building10.0030.9-7.484.129.4-30.97.47.27.8no
Conditioned merge + Single zone per floor type30.0030.7-8.368.825.6-30.78.38.14.3no
Conditioned merge + Stacked floor zone multiplier30.0031.4-6.966.822.8-31.46.96.55.8no
Semantic merge + Single zone per floor type30.0030.9-8.669.225.9-30.98.68.24.1no
Semantic merge + Stack600.00-0.0-0.11.70.40.00.10.2-0.1yes
Semantic merge + Stacked floor zone multiplier600.001.21.710.55.8-1.2-1.7-2.11.1yes
No simplification + Stacked floor zone multiplier650.001.31.710.46.0-1.3-1.7-1.91.1yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2019 · 0°

Reference 69d5b690b683ab38/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 32.2 and cooling 26.5 kWh/m²; peak heating 382.1 and cooling 167.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0023.5-6.573.032.5-23.56.57.48.7no
Semantic merge + Single zone building10.0023.8-7.073.532.6-23.87.07.48.5no
Conditioned merge + Single zone per floor type30.0023.7-7.956.930.2-23.77.98.48.2no
Conditioned merge + Stacked floor zone multiplier30.0024.4-6.556.126.5-24.46.56.47.2no
Semantic merge + Single zone per floor type30.0024.0-8.357.330.5-24.08.38.48.0no
Semantic merge + Stack600.00-0.2-0.21.81.50.20.2-0.20.1yes
Semantic merge + Stacked floor zone multiplier600.000.71.29.84.9-0.7-1.2-2.0-0.3yes
No simplification + Stacked floor zone multiplier650.000.91.59.85.6-0.9-1.5-1.9-0.3yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2019 · 45°

Reference 81d6bdc5a9a1ee70/R: No simplification + Stack, 65 zones, 4,982 m² conditioned; annual sensible heating 32.6 and cooling 27.6 kWh/m²; peak heating 382.7 and cooling 170.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.0024.2-4.972.430.4-24.24.97.38.1no
Semantic merge + Single zone building10.0024.5-5.472.930.5-24.55.47.37.9no
Conditioned merge + Single zone per floor type30.0024.4-6.256.728.4-24.46.28.38.1no
Conditioned merge + Stacked floor zone multiplier30.0025.0-5.055.724.8-25.05.06.46.9no
Semantic merge + Single zone per floor type30.0024.7-6.757.128.5-24.76.78.37.9no
Semantic merge + Stack600.00-0.1-0.11.40.50.10.1-0.10.0yes
Semantic merge + Stacked floor zone multiplier600.000.71.29.65.2-0.7-1.2-2.0-0.5yes
No simplification + Stacked floor zone multiplier650.000.81.39.55.5-0.8-1.3-1.9-0.5yes
11 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 3 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 3 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Perimeter core 4.57 m + Single zone building → Conditioned merge + Single zone building
  • Perimeter core 4.57 m + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

Atlas programs

Program key90.1-200790.1-2019
MediumOffice - Classroom90-1-2007.medium-office-detailed.source.medium-office-classroom.97604290-1-2019.medium-office-detailed.source.medium-office-classroom.f3ffcc
MediumOffice - ClosedOffice90-1-2007.medium-office-detailed.source.medium-office-closed-office.dc8d6490-1-2019.medium-office-detailed.source.medium-office-closed-office.cbb047
MediumOffice - Conference90-1-2007.medium-office-detailed.source.medium-office-conference.4c328690-1-2019.medium-office-detailed.source.medium-office-conference.bca6b6
MediumOffice - Corridor90-1-2007.medium-office-detailed.source.medium-office-corridor.12565490-1-2019.medium-office-detailed.source.medium-office-corridor.5d79bb
MediumOffice - Dining90-1-2007.medium-office-detailed.source.medium-office-dining.a5af7190-1-2019.medium-office-detailed.source.medium-office-dining.304fc7
MediumOffice - Elec/MechRoom90-1-2007.medium-office-detailed.source.medium-office-elec-mech-room.08b1d490-1-2019.medium-office-detailed.source.medium-office-elec-mech-room.298343
MediumOffice - Lobby90-1-2007.medium-office-detailed.source.medium-office-lobby.2defdf90-1-2019.medium-office-detailed.source.medium-office-lobby.ca7d4c
MediumOffice - OpenOffice90-1-2007.medium-office-detailed.source.medium-office-open-office.9579b390-1-2019.medium-office-detailed.source.medium-office-open-office.076b5d
MediumOffice - Restroom90-1-2007.medium-office-detailed.source.medium-office-restroom.dab60390-1-2019.medium-office-detailed.source.medium-office-restroom.da2f17
MediumOffice - Stair90-1-2007.medium-office-detailed.source.medium-office-stair.b4edfd90-1-2019.medium-office-detailed.source.medium-office-stair.72905a
MediumOffice - Storage90-1-2007.medium-office-detailed.source.medium-office-storage.7d0fd990-1-2019.medium-office-detailed.source.medium-office-storage.2cc33c

The atlas programs each program key of the prototype takes, as the suite's saved inputs name them (release 2.4.0 IDs); the prototype's geometry and glazing are BEMGen's DOE record. Method and caveats.