Outpatient zoning

Outpatient · geometric LOD study drop 5 · atlas inputs release 2.4.0 · BEMGen 99c0b0adcd44

Prototype
Outpatient
Cells
24: 6 climate zones × 2 vintages × 2 orientations
Cells with a recommended zoning
24 of 24
Robust across orientations
12 of 12 cell pairs: Conditioned merge + Single zone building (6)
Reference zoning
No simplification + Stack
Reference zones
126
Most often recommended
Conditioned merge + Single zone building (12 of 24 cells)
Serial cost (R5)
timed in 1 of 24 cells (3C 90.1-2019 0°)
LOD recommendations 1.2.0, this prototype Downloadrelease 2.4.0 · SHA-256 29ea9f53d705f10c2e82eef4988f813995fc9ee8a404d6924f77bf56d3e4beaa

Robust across orientations

Robust across orientations in 12 of 12 cell pairs (0° and 45°).

Climate zoneVintageRobust zoningZonesHeating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Area change %CPU ratioWall ratioMemory ratioPer orientation

For each prototype, climate zone and vintage, the robust zoning is the coarsest (fewest modelled zones) that meets the threshold at every orientation of the cell pair, by the writer's own verdict on each zoning at each orientation, with at most the reference's zone count, as the writer bounds a recommendation (D-220); a duplicate never meets, as the writer lists it. Ties at the fewest zones go to a zoning both orientations recommend, else to the first in the study's zoning order (simplifier, join pieces, perimeter depth, stacker, IWHT, FHT); the tied zonings are named. The errors reported are the worse of the orientations' values for each metric, so the row is a bound, not a mean; the cost ratios are the medians over the timed sites of that zoning in the pair. Where both orientations recommend the same zoning it is the robust one. A pair where no zoning meets the threshold at both orientations says so and names each orientation's own recommendation; the per-orientation rows below stay the reading for one orientation. The cost ratios are the median over the timed sites of the robust zoning in the pair (in this drop one orientation at most is timed, so the ratio is that site's); not timed where none is. The rule and its limits.

Every zoning by cell

2A · 90.1-2007 · 0°

Reference 37d67e4d513256b9/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.1 and cooling 182.3 kWh/m²; peak heating 13.6 and cooling 176.3 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-98.3-0.5775.92.198.30.5-71.1-1.2yes
Conditioned merge + Stacked floor zone multiplier30.00-88.7-0.4653.81.888.70.4-28.6-0.3yes
Semantic merge + Single zone per floor type30.00-98.3-0.5775.92.198.30.5-71.1-1.2yes
Semantic merge + Stack1040.00-3.8-0.041.50.13.80.0-2.2-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0036.10.1301.71.1-36.1-0.135.80.9yes
No simplification + Stacked floor zone multiplier1260.0042.50.1337.71.1-42.5-0.139.10.9yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2A · 90.1-2007 · 45°

Reference 0864799c6de45322/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.1 and cooling 180.0 kWh/m²; peak heating 11.6 and cooling 171.9 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-99.6-0.5759.22.199.60.5-91.0-1.2yes
Conditioned merge + Stacked floor zone multiplier30.00-95.5-0.5696.61.895.50.5-43.2-0.4yes
Semantic merge + Single zone per floor type30.00-99.6-0.5759.22.199.60.5-91.0-1.2yes
Semantic merge + Stack1040.00-5.0-0.031.60.15.00.0-1.6-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0030.30.1245.11.0-30.3-0.134.30.7yes
No simplification + Stacked floor zone multiplier1260.0037.90.1267.21.0-37.9-0.136.30.8yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2A · 90.1-2019 · 0°

Reference 21623b36d829628e/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.0 and cooling 165.9 kWh/m²; peak heating 4.4 and cooling 183.8 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00–-0.9–3.2–0.9-100.0-2.8yes
Conditioned merge + Stacked floor zone multiplier30.00–-0.9–3.3–0.9-100.0-2.7yes
Semantic merge + Single zone per floor type30.00–-0.9–3.2–0.9-100.0-2.8yes
Semantic merge + Stack1040.00–-0.0–0.1–0.0-2.8-0.1yes
Semantic merge + Stacked floor zone multiplier1040.00–0.0–0.7–-0.033.3-0.5yes
No simplification + Stacked floor zone multiplier1260.00–0.1–0.7–-0.141.2-0.4yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2A · 90.1-2019 · 45°

Reference 9f1850eb5127ef51/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.0 and cooling 163.5 kWh/m²; peak heating 4.4 and cooling 181.5 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00–-1.0–3.2–1.0-100.0-3.7yes
Conditioned merge + Stacked floor zone multiplier30.00–-0.9–3.3–0.9-100.0-4.2yes
Semantic merge + Single zone per floor type30.00–-1.0–3.2–1.0-100.0-3.7yes
Semantic merge + Stack1040.00–-0.0–0.1–0.0-3.0-0.1yes
Semantic merge + Stacked floor zone multiplier1040.00–0.0–0.7–-0.014.5-0.5yes
No simplification + Stacked floor zone multiplier1260.00–0.1–0.7–-0.122.4-0.4yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2007 · 0°

Reference 433442b2c7800bcd/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.6 and cooling 175.9 kWh/m²; peak heating 22.1 and cooling 185.1 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-97.8-1.1402.62.997.81.1-61.5-1.0yes
Conditioned merge + Stacked floor zone multiplier30.00-86.8-0.9336.72.786.80.9-25.0-0.3yes
Semantic merge + Single zone per floor type30.00-97.8-1.1402.62.997.81.1-61.5-1.0yes
Semantic merge + Stack1040.00-3.7-0.020.00.13.70.0-3.2-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0032.00.2153.61.2-32.0-0.228.30.8yes
No simplification + Stacked floor zone multiplier1260.0037.50.3172.21.2-37.5-0.329.50.8yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2007 · 45°

Reference 3803b314f15579ea/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.6 and cooling 174.1 kWh/m²; peak heating 18.2 and cooling 184.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-99.2-1.1410.22.999.21.1-72.1-1.1yes
Conditioned merge + Stacked floor zone multiplier30.00-94.1-1.0372.82.794.11.0-39.5-0.3yes
Semantic merge + Single zone per floor type30.00-99.2-1.1410.22.999.21.1-72.1-1.1yes
Semantic merge + Stack1040.00-4.1-0.015.80.14.10.0-2.9-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0028.00.2135.41.1-28.0-0.230.00.7yes
No simplification + Stacked floor zone multiplier1260.0033.20.2145.41.1-33.2-0.232.20.7yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2019 · 0°

Reference 0d64f9ccb96c659a/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.2 and cooling 161.2 kWh/m²; peak heating 8.9 and cooling 189.5 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-100.0-1.5452.84.3100.01.5-100.0-1.4yes
Conditioned merge + Stacked floor zone multiplier30.00-99.1-1.4440.74.399.11.4-50.6-1.8yes
Semantic merge + Single zone per floor type30.00-100.0-1.5452.84.3100.01.5-100.0-1.4yes
Semantic merge + Stack1040.00-4.8-0.022.70.24.80.0-7.80.0yes
Semantic merge + Stacked floor zone multiplier1040.0020.90.1107.10.8-20.9-0.147.9-0.5yes
No simplification + Stacked floor zone multiplier1260.0030.80.1141.70.9-30.8-0.154.7-0.5yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

2B · 90.1-2019 · 45°

Reference 2041ca8bbbcfbedf/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.2 and cooling 159.0 kWh/m²; peak heating 7.6 and cooling 185.9 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-100.0-1.5456.04.3100.01.5-100.0-2.2yes
Conditioned merge + Stacked floor zone multiplier30.00-99.9-1.4453.94.299.91.4-87.3-2.5yes
Semantic merge + Single zone per floor type30.00-100.0-1.5456.04.3100.01.5-100.0-2.2yes
Semantic merge + Stack1040.00-6.2-0.024.90.16.20.0-8.3-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0018.80.180.90.8-18.8-0.133.4-0.7yes
No simplification + Stacked floor zone multiplier1260.0031.60.1120.90.8-31.6-0.136.2-0.6yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2007 · 0°

Reference 22f556b310266f14/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.4 and cooling 136.8 kWh/m²; peak heating 10.1 and cooling 146.7 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-99.9-1.7363.02.799.91.7-90.3-1.1yes
Conditioned merge + Stacked floor zone multiplier30.00-98.0-1.5344.82.998.01.5-40.70.0yes
Semantic merge + Single zone per floor type30.00-99.9-1.7363.02.899.91.7-90.3-1.2yes
Semantic merge + Stack1040.00-3.5-0.115.00.23.50.1-3.0-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0032.70.3159.51.1-32.7-0.359.71.1yes
No simplification + Stacked floor zone multiplier1260.0039.70.4175.51.1-39.7-0.450.71.1yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2007 · 45°

Reference 4176838c890be51e/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.4 and cooling 138.7 kWh/m²; peak heating 9.0 and cooling 144.5 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-100.0-1.6356.22.6100.01.6-100.0-1.1yes
Conditioned merge + Stacked floor zone multiplier30.00-99.7-1.5352.22.899.71.5-71.8-0.1yes
Semantic merge + Single zone per floor type30.00-100.0-1.7356.22.7100.01.7-100.0-1.2yes
Semantic merge + Stack1040.00-4.6-0.016.60.14.60.0-0.5-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0025.70.3126.21.0-25.7-0.347.70.9yes
No simplification + Stacked floor zone multiplier1260.0033.90.3138.81.0-33.9-0.349.10.9yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2019 · 0°

Reference 09e2c5a5a43363a4/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.3 and cooling 130.5 kWh/m²; peak heating 5.3 and cooling 158.1 kW. Sensible heating is below 1 kWh/m² and is not judged. Serial cost (R5): processor time 49.3 s, wall clock 49.6 s, peak committed memory 303 MiB, each the median of 3 repeats (processor-time CV 2.7 %); a zoning's ratios are its own medians over the reference's.

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %CPU ratioWall ratioMemory ratioMeets the threshold
Conditioned merge + Single zone per floor type30.00-100.0-2.8301.07.0100.02.8-100.01.00.0620.0640.694yes
Conditioned merge + Stacked floor zone multiplier30.00-100.0-2.6301.06.4100.02.6-100.01.00.0630.0630.692yes
Semantic merge + Single zone per floor type30.00-100.0-2.8301.07.0100.02.8-100.01.00.0640.0640.753yes
Semantic merge + Stack1040.00-4.4-0.114.60.24.40.1-6.70.00.8690.8781.031yes
Semantic merge + Stacked floor zone multiplier1040.0020.70.251.70.9-20.7-0.219.50.20.7850.7991.043yes
No simplification + Stacked floor zone multiplier1260.0032.00.383.61.0-32.0-0.330.80.20.8920.8970.945yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

3C · 90.1-2019 · 45°

Reference 02c419ab81d59876/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 0.3 and cooling 130.6 kWh/m²; peak heating 5.2 and cooling 154.6 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone per floor type30.00-100.0-2.7312.56.9100.02.7-100.00.9yes
Conditioned merge + Stacked floor zone multiplier30.00-100.0-2.5312.56.2100.02.5-100.00.8yes
Semantic merge + Single zone per floor type30.00-100.0-2.7312.56.9100.02.7-100.00.9yes
Semantic merge + Stack1040.00-4.6-0.115.60.24.60.1-4.6-0.0yes
Semantic merge + Stacked floor zone multiplier1040.0019.20.151.20.8-19.2-0.14.00.1yes
No simplification + Stacked floor zone multiplier1260.0031.70.284.30.9-31.7-0.221.50.1yes
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2007 · 0°

Reference f64f36bb55e73e9b/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 2.9 and cooling 136.4 kWh/m²; peak heating 36.7 and cooling 172.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-99.1-3.9259.811.099.13.9-65.82.8no
Semantic merge + Single zone building10.00-99.1-3.9259.811.099.13.9-65.72.7no
Conditioned merge + Single zone per floor type30.00-88.5-3.3211.35.888.53.3-47.4-1.2no
Conditioned merge + Stacked floor zone multiplier30.00-55.3-2.2154.64.455.32.2-19.7-0.0no
Semantic merge + Single zone per floor type30.00-88.5-3.3211.35.888.53.3-47.4-1.2no
Semantic merge + Stacked floor zone multiplier1040.0042.21.2106.02.4-42.2-1.211.61.1no
No simplification + Stacked floor zone multiplier1260.0045.91.3112.62.5-45.9-1.315.61.1no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2007 · 45°

Reference 24585b759fbb1acf/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 2.6 and cooling 135.6 kWh/m²; peak heating 31.6 and cooling 164.6 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-99.9-3.7256.210.499.93.7-90.22.4no
Semantic merge + Single zone building10.00-99.9-3.8256.210.499.93.8-90.12.4no
Conditioned merge + Single zone per floor type30.00-93.5-3.3224.05.793.53.3-53.1-1.1no
Conditioned merge + Stacked floor zone multiplier30.00-66.8-2.4171.74.566.82.4-19.3-0.2no
Semantic merge + Single zone per floor type30.00-93.5-3.3224.05.793.53.3-53.1-1.2no
Semantic merge + Stacked floor zone multiplier1040.0040.71.1104.42.1-40.7-1.116.30.9no
No simplification + Stacked floor zone multiplier1260.0043.81.2108.82.2-43.8-1.220.71.0no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2019 · 0°

Reference 3c48edec1939ad23/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 1.7 and cooling 129.0 kWh/m²; peak heating 24.9 and cooling 185.8 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-100.0-3.9259.09.8100.03.9-100.0-2.2no
Semantic merge + Single zone building10.00-100.0-3.9259.09.8100.03.9-100.0-2.2no
Conditioned merge + Single zone per floor type30.00-98.3-3.5247.77.798.33.5-64.2-1.2no
Conditioned merge + Stacked floor zone multiplier30.00-80.8-3.0204.87.280.83.0-23.0-1.4no
Semantic merge + Single zone per floor type30.00-98.3-3.6247.77.798.33.6-64.2-1.2no
Semantic merge + Stacked floor zone multiplier1040.0029.60.6113.01.7-29.6-0.623.8-0.3no
No simplification + Stacked floor zone multiplier1260.0036.30.8121.51.9-36.3-0.827.4-0.3no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

4A · 90.1-2019 · 45°

Reference f93d860435820270/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 1.7 and cooling 127.2 kWh/m²; peak heating 22.0 and cooling 178.7 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-100.0-3.9252.39.7100.03.9-100.0-2.8no
Semantic merge + Single zone building10.00-100.0-3.9252.39.7100.03.9-100.0-2.8no
Conditioned merge + Single zone per floor type30.00-99.5-3.6248.37.799.53.6-70.9-1.9no
Conditioned merge + Stacked floor zone multiplier30.00-86.8-3.1213.27.386.83.1-29.6-2.2no
Semantic merge + Single zone per floor type30.00-99.5-3.6248.37.899.53.6-70.9-1.9no
Semantic merge + Stacked floor zone multiplier1040.0027.00.6105.51.5-27.0-0.631.2-0.5no
No simplification + Stacked floor zone multiplier1260.0034.00.7110.61.7-34.0-0.732.4-0.4no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2007 · 0°

Reference 9e05cfddcdba0a76/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 6.5 and cooling 118.0 kWh/m²; peak heating 56.2 and cooling 167.3 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-91.7-7.3198.916.191.77.3-18.12.9no
Semantic merge + Single zone building10.00-91.7-7.4198.816.191.77.4-17.92.9no
Conditioned merge + Single zone per floor type30.00-74.8-6.1149.39.974.86.1-38.0-1.1no
Conditioned merge + Stacked floor zone multiplier30.00-43.9-4.1108.06.843.94.1-30.2-0.0no
Semantic merge + Single zone per floor type30.00-74.8-6.2149.29.974.86.2-37.9-1.1no
Semantic merge + Stacked floor zone multiplier1040.0030.32.061.53.3-30.3-2.06.21.2no
No simplification + Stacked floor zone multiplier1260.0033.02.265.83.7-33.0-2.27.61.2no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2007 · 45°

Reference b19d35adf4e53040/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 5.6 and cooling 118.9 kWh/m²; peak heating 48.7 and cooling 161.5 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-96.0-6.9208.715.096.06.9-31.52.0no
Semantic merge + Single zone building10.00-96.0-6.9208.615.096.06.9-31.42.0no
Conditioned merge + Single zone per floor type30.00-82.2-5.9164.99.482.25.9-42.4-1.2no
Conditioned merge + Stacked floor zone multiplier30.00-52.4-4.2120.96.752.44.2-28.9-0.1no
Semantic merge + Single zone per floor type30.00-82.2-6.0164.99.582.26.0-42.3-1.2no
Semantic merge + Stacked floor zone multiplier1040.0032.21.866.33.1-32.2-1.84.91.0no
No simplification + Stacked floor zone multiplier1260.0034.42.069.63.3-34.4-2.08.71.1no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2019 · 0°

Reference 92c9bff9d9f5796f/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 3.4 and cooling 114.3 kWh/m²; peak heating 40.8 and cooling 177.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-99.1-5.9239.013.399.15.9-53.3-0.5no
Semantic merge + Single zone building10.00-99.1-5.9238.913.399.15.9-53.1-0.5no
Conditioned merge + Single zone per floor type30.00-90.5-5.3201.210.390.55.3-57.2-0.3no
Conditioned merge + Stacked floor zone multiplier30.00-59.8-4.1149.18.859.84.1-29.7-0.1no
Semantic merge + Single zone per floor type30.00-90.5-5.4201.210.390.55.4-57.2-0.3no
Semantic merge + Stacked floor zone multiplier1040.0035.21.395.42.8-35.2-1.33.20.2no
No simplification + Stacked floor zone multiplier1260.0039.81.5102.13.2-39.8-1.510.00.2no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

5A · 90.1-2019 · 45°

Reference 5ba06c1950095f70/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 3.1 and cooling 113.7 kWh/m²; peak heating 36.0 and cooling 170.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-99.8-5.7236.312.899.85.7-81.4-1.6no
Semantic merge + Single zone building10.00-99.8-5.7236.312.899.85.7-80.9-1.7no
Conditioned merge + Single zone per floor type30.00-94.5-5.3210.310.294.55.3-61.7-1.0no
Conditioned merge + Stacked floor zone multiplier30.00-67.9-4.2160.78.867.94.2-30.2-0.8no
Semantic merge + Single zone per floor type30.00-94.5-5.3210.310.294.55.3-61.7-1.0no
Semantic merge + Stacked floor zone multiplier1040.0034.31.295.72.7-34.3-1.28.70.0no
No simplification + Stacked floor zone multiplier1260.0038.81.4100.22.9-38.8-1.413.80.1no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2007 · 0°

Reference aede1f70709c04db/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 15.2 and cooling 109.2 kWh/m²; peak heating 111.5 and cooling 170.5 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-66.1-10.8130.721.866.110.84.22.6no
Semantic merge + Single zone building10.00-66.1-10.9130.621.866.110.94.32.6no
Conditioned merge + Single zone per floor type30.00-53.7-9.195.015.153.79.1-13.7-1.0no
Conditioned merge + Stacked floor zone multiplier30.00-35.7-6.474.611.135.76.4-15.2-0.0no
Semantic merge + Single zone per floor type30.00-53.7-9.294.915.153.79.2-13.6-1.0no
Semantic merge + Stacked floor zone multiplier1040.0017.02.632.24.2-17.0-2.62.00.9no
No simplification + Stacked floor zone multiplier1260.0019.02.934.84.7-19.0-2.92.00.9no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2007 · 45°

Reference 8fdd605e18be09d8/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 13.4 and cooling 108.6 kWh/m²; peak heating 105.9 and cooling 166.7 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-72.5-10.7142.921.472.510.7-0.21.7no
Semantic merge + Single zone building10.00-72.5-10.8142.821.472.510.8-0.11.6no
Conditioned merge + Single zone per floor type30.00-57.9-8.9102.414.557.98.9-19.3-1.1no
Conditioned merge + Stacked floor zone multiplier30.00-37.8-6.378.110.337.86.3-21.6-0.2no
Semantic merge + Single zone per floor type30.00-57.9-9.0102.414.557.99.0-19.2-1.1no
Semantic merge + Stacked floor zone multiplier1040.0019.22.635.84.1-19.2-2.62.30.9no
No simplification + Stacked floor zone multiplier1260.0020.82.937.94.5-20.8-2.92.20.9no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2019 · 0°

Reference 20b532e49193b1e3/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 8.4 and cooling 105.2 kWh/m²; peak heating 86.1 and cooling 180.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-82.1-9.0171.819.082.19.0-1.5-1.8no
Semantic merge + Single zone building10.00-82.1-9.1171.719.082.19.1-1.4-1.8no
Conditioned merge + Single zone per floor type30.00-71.5-8.1136.715.171.58.1-24.5-0.8no
Conditioned merge + Stacked floor zone multiplier30.00-48.0-6.2106.311.748.06.2-24.7-0.9no
Semantic merge + Single zone per floor type30.00-71.5-8.2136.715.171.58.2-24.4-0.9no
Semantic merge + Stacked floor zone multiplier1040.0022.42.049.23.7-22.4-2.05.4-0.3no
No simplification + Stacked floor zone multiplier1260.0025.72.353.54.3-25.7-2.35.0-0.3no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

7A · 90.1-2019 · 45°

Reference 823c8d754428ff88/R: No simplification + Stack, 126 zones, 3,915 m² conditioned; annual sensible heating 7.7 and cooling 103.7 kWh/m²; peak heating 80.6 and cooling 172.0 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-86.0-8.9179.418.686.08.9-5.0-2.3no
Semantic merge + Single zone building10.00-85.9-8.9179.318.685.98.9-4.9-2.3no
Conditioned merge + Single zone per floor type30.00-75.3-8.0143.914.775.38.0-28.4-1.5no
Conditioned merge + Stacked floor zone multiplier30.00-50.4-6.1109.811.450.46.1-26.9-1.9no
Semantic merge + Single zone per floor type30.00-75.3-8.1143.914.875.38.1-28.3-1.5no
Semantic merge + Stacked floor zone multiplier1040.0024.42.053.33.8-24.4-2.04.4-0.5no
No simplification + Stacked floor zone multiplier1260.0027.42.356.74.2-27.4-2.34.0-0.4no
8 zonings not generated: the generator refuses them by a documented limit, so they were never simulated
  • Perimeter core 3 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 3 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone building: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Single zone per floor type: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stack: a wing is narrower than twice the perimeter depth
  • Perimeter core 4.57 m + Stacked floor zone multiplier: a wing is narrower than twice the perimeter depth
7 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Stack → Conditioned merge + Single zone per floor type
  • No simplification + Single zone building → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stack → Conditioned merge + Single zone per floor type
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Stacked floor zone multiplier

Atlas programs

Program key90.1-200790.1-2019
Anesthesia90-1-2007.outpatient.source.anesthesia.c4a9bb90-1-2019.outpatient.source.anesthesia.78a1aa
BioHazard90-1-2007.outpatient.source.bio-hazard.1e906090-1-2019.outpatient.source.bio-hazard.67c527
Cafe90-1-2007.outpatient.source.cafe.c38de990-1-2019.outpatient.source.cafe.27e081
CleanWork90-1-2007.outpatient.source.clean-work.1da9b390-1-2019.outpatient.source.clean-work.432a15
Conference90-1-2007.outpatient.source.conference.b84ab290-1-2019.outpatient.source.conference.d7ab49
DressingRoom90-1-2007.outpatient.source.dressing-room.d610e390-1-2019.outpatient.source.dressing-room.00572b
Elec/MechRoom90-1-2007.outpatient.source.elec-mech-room.ecdd8490-1-2019.outpatient.source.elec-mech-room.86ad15
ElevatorPumpRoom90-1-2007.outpatient.source.elevator-pump-room.3d42c890-1-2019.outpatient.source.elevator-pump-room.daca39
Exam90-1-2007.outpatient.source.exam.0119ab90-1-2019.outpatient.source.exam.69b6bf
Hall90-1-2007.outpatient.source.hall.c3092990-1-2019.outpatient.source.hall.039894
Hall_infil90-1-2007.outpatient.source.hall-infil.70c5f590-1-2019.outpatient.source.hall-infil.ab3266
IT_Room90-1-2007.outpatient.source.it-room.b4c9a290-1-2019.outpatient.source.it-room.457f9d
Janitor90-1-2007.outpatient.source.janitor.e4ac8890-1-2019.outpatient.source.janitor.4d600e
Lobby90-1-2007.outpatient.source.lobby.851d8d90-1-2019.outpatient.source.lobby.9d6671
LockerRoom90-1-2007.outpatient.source.locker-room.968a8690-1-2019.outpatient.source.locker-room.91af92
Lounge90-1-2007.outpatient.source.lounge.3d98e090-1-2019.outpatient.source.lounge.afd6c4
MRI90-1-2007.outpatient.source.mri.cf9fd990-1-2019.outpatient.source.mri.37e4e0
MRI_Control90-1-2007.outpatient.source.mri-control.1b09f190-1-2019.outpatient.source.mri-control.efbc7d
MedGas90-1-2007.outpatient.source.med-gas.e157d890-1-2019.outpatient.source.med-gas.9c4b0b
NurseStation90-1-2007.outpatient.source.nurse-station.d2b32490-1-2019.outpatient.source.nurse-station.f389f0
OR90-1-2007.outpatient.source.or.5ad2a490-1-2019.outpatient.source.or.f33cca
Office90-1-2007.outpatient.source.office.59af0890-1-2019.outpatient.source.office.6e06bc
PACU90-1-2007.outpatient.source.pacu.09193190-1-2019.outpatient.source.pacu.210264
PhysicalTherapy90-1-2007.outpatient.source.physical-therapy.772d9f90-1-2019.outpatient.source.physical-therapy.981d35
PreOp90-1-2007.outpatient.source.pre-op.0365c390-1-2019.outpatient.source.pre-op.8cf791
ProcedureRoom90-1-2007.outpatient.source.procedure-room.38cece90-1-2019.outpatient.source.procedure-room.cce99d
Reception90-1-2007.outpatient.source.reception.76719090-1-2019.outpatient.source.reception.bc28a8
Soil Work90-1-2007.outpatient.source.soil-work.298bbe90-1-2019.outpatient.source.soil-work.80da4c
Stair90-1-2007.outpatient.source.stair.f8570b90-1-2019.outpatient.source.stair.6df467
Toilet90-1-2007.outpatient.source.toilet.fc1f0d90-1-2019.outpatient.source.toilet.c210cd
Undeveloped90-1-2007.outpatient.source.undeveloped.18cb1090-1-2019.outpatient.source.undeveloped.52f248
Xray90-1-2007.outpatient.source.xray.ef1afb90-1-2019.outpatient.source.xray.ee423c

The atlas programs each program key of the prototype takes, as the suite's saved inputs name them (release 2.4.0 IDs); the prototype's geometry and glazing are BEMGen's DOE record. Method and caveats.