Stand-alone retail zoning

StandAloneRetail · geometric LOD study drop 5 · atlas inputs release 2.4.0 · BEMGen 99c0b0adcd44

Prototype
StandAloneRetail
Cells
24: 6 climate zones × 2 vintages × 2 orientations
Cells with a recommended zoning
22 of 24
Robust across orientations
11 of 12 cell pairs: Conditioned merge + Single zone building (7)
Reference zoning
No simplification + Stack
Reference zones
5
Most often recommended
Conditioned merge + Single zone building (15 of 24 cells)
Serial cost (R5)
timed in 1 of 24 cells (5A 90.1-2019 0°)
LOD recommendations 1.2.0, this prototype Downloadrelease 2.4.0 · SHA-256 3c4abf86c9654ce03d9b72a049e2c23cd360236a4880a73503cb0cebe2dc3ff9

Robust across orientations

Robust across orientations in 11 of 12 cell pairs (0° and 45°).

Climate zoneVintageRobust zoningZonesHeating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Area change %CPU ratioWall ratioMemory ratioPer orientation
4A90.1-2019none meets the threshold at both orientations0°: none · 45°: none

For each prototype, climate zone and vintage, the robust zoning is the coarsest (fewest modelled zones) that meets the threshold at every orientation of the cell pair, by the writer's own verdict on each zoning at each orientation, with at most the reference's zone count, as the writer bounds a recommendation (D-220); a duplicate never meets, as the writer lists it. Ties at the fewest zones go to a zoning both orientations recommend, else to the first in the study's zoning order (simplifier, join pieces, perimeter depth, stacker, IWHT, FHT); the tied zonings are named. The errors reported are the worse of the orientations' values for each metric, so the row is a bound, not a mean; the cost ratios are the medians over the timed sites of that zoning in the pair. Where both orientations recommend the same zoning it is the robust one. A pair where no zoning meets the threshold at both orientations says so and names each orientation's own recommendation; the per-orientation rows below stay the reading for one orientation. The cost ratios are the median over the timed sites of the robust zoning in the pair (in this drop one orientation at most is timed, so the ratio is that site's); not timed where none is. The rule and its limits.

Every zoning by cell

2A · 90.1-2007 · 0°

Reference 62297364c00228e9/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.0 and cooling 117.8 kWh/m²; peak heating 7.5 and cooling 80.2 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.00–-4.9–7.8–4.940.3-4.1yes
Perimeter core 4.57 m + Stack50.00–-4.9–6.5–4.914.6-2.5yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 62297364c00228e9/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 62297364c00228e9/R
  • Semantic merge + Stacked floor zone multiplier → 62297364c00228e9/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

2A · 90.1-2007 · 45°

Reference f3fef36a8ea7a0fd/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.0 and cooling 114.5 kWh/m²; peak heating 3.4 and cooling 76.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.00–-3.1–4.7–3.168.9-3.0yes
Perimeter core 4.57 m + Stack50.00–-3.7–4.6–3.741.0-1.8yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → f3fef36a8ea7a0fd/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → f3fef36a8ea7a0fd/R
  • Semantic merge + Stacked floor zone multiplier → f3fef36a8ea7a0fd/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

2A · 90.1-2019 · 0°

Reference 75c475ef3faaf5e2/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.0 and cooling 96.1 kWh/m²; peak heating 5.7 and cooling 75.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.00–-7.2–12.9–7.225.4-0.6yes
Perimeter core 4.57 m + Stack50.00–-6.8–11.4–6.84.30.0yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 75c475ef3faaf5e2/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 75c475ef3faaf5e2/R
  • Semantic merge + Stacked floor zone multiplier → 75c475ef3faaf5e2/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

2A · 90.1-2019 · 45°

Reference 98895ed905856ba1/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.0 and cooling 92.5 kWh/m²; peak heating 4.1 and cooling 71.8 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.00–-5.3–13.1–5.347.30.1yes
Perimeter core 4.57 m + Stack50.00–-5.8–11.5–5.837.80.3yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 98895ed905856ba1/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 98895ed905856ba1/R
  • Semantic merge + Stacked floor zone multiplier → 98895ed905856ba1/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

2B · 90.1-2007 · 0°

Reference 2d656ea3438c8226/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.2 and cooling 108.3 kWh/m²; peak heating 15.7 and cooling 87.3 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.0043.0-4.7341.78.4-43.04.711.3-3.5yes
Perimeter core 4.57 m + Stack50.006.1-4.8175.67.1-6.14.86.5-2.3yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 2d656ea3438c8226/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 2d656ea3438c8226/R
  • Semantic merge + Stacked floor zone multiplier → 2d656ea3438c8226/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

2B · 90.1-2007 · 45°

Reference 56fe5c405091e23d/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.1 and cooling 104.2 kWh/m²; peak heating 10.5 and cooling 84.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.0081.6-2.6596.35.1-81.62.616.8-2.5yes
Perimeter core 4.57 m + Stack50.0041.3-3.4368.84.9-41.33.419.9-1.7yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 56fe5c405091e23d/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 56fe5c405091e23d/R
  • Semantic merge + Stacked floor zone multiplier → 56fe5c405091e23d/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

2B · 90.1-2019 · 0°

Reference c83f4cfeb0c80588/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.3 and cooling 87.9 kWh/m²; peak heating 15.6 and cooling 83.1 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.0018.3-6.8323.214.7-18.36.8-10.0-0.2yes
Perimeter core 4.57 m + Stack50.00-3.2-6.6266.312.53.26.6-8.90.0yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → c83f4cfeb0c80588/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → c83f4cfeb0c80588/R
  • Semantic merge + Stacked floor zone multiplier → c83f4cfeb0c80588/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

2B · 90.1-2019 · 45°

Reference 30e445abdaed14ec/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.3 and cooling 83.5 kWh/m²; peak heating 13.7 and cooling 80.5 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.0038.9-4.5402.615.3-38.94.5-7.80.9yes
Perimeter core 4.57 m + Stack50.0015.1-5.1313.112.6-15.15.1-5.50.5yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 30e445abdaed14ec/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 30e445abdaed14ec/R
  • Semantic merge + Stacked floor zone multiplier → 30e445abdaed14ec/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

3C · 90.1-2007 · 0°

Reference 9670cf44273b3808/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.1 and cooling 52.4 kWh/m²; peak heating 9.4 and cooling 59.4 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-98.7-10.0865.413.098.710.0-72.9-3.0no
No simplification + Single zone building10.00-98.7-10.0865.313.098.710.0-72.9-2.9no
Perimeter core 3 m + Single zone building10.00-98.7-10.0864.813.098.710.0-72.6-2.9no
Perimeter core 4.57 m + Single zone building10.00-98.7-10.0864.513.098.710.0-72.5-2.9no
Single zone per floor + Stack10.00-98.7-10.0865.413.098.710.0-72.9-3.0no
16 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 9670cf44273b3808/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 9670cf44273b3808/R
  • Semantic merge + Stacked floor zone multiplier → 9670cf44273b3808/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Single zone per floor + Stack

3C · 90.1-2007 · 45°

Reference 549a20d16e25a418/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.1 and cooling 51.7 kWh/m²; peak heating 6.4 and cooling 57.1 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.00–0.9–7.2–-0.922.0-3.8yes
Perimeter core 4.57 m + Stack50.00–-2.8–9.7–2.813.6-4.4yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 549a20d16e25a418/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 549a20d16e25a418/R
  • Semantic merge + Stacked floor zone multiplier → 549a20d16e25a418/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

3C · 90.1-2019 · 0°

Reference 22f5af54b7bdcd97/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.2 and cooling 38.0 kWh/m²; peak heating 9.9 and cooling 51.0 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-98.3-12.2686.117.698.312.2-37.5-4.8no
No simplification + Single zone building10.00-98.3-12.2686.117.698.312.2-37.4-4.6no
Perimeter core 3 m + Single zone building10.00-98.3-12.2686.117.698.312.2-37.1-4.7no
Perimeter core 4.57 m + Single zone building10.00-98.3-12.2686.117.698.312.2-37.0-4.7no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 22f5af54b7bdcd97/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 22f5af54b7bdcd97/R
  • Semantic merge + Stacked floor zone multiplier → 22f5af54b7bdcd97/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

3C · 90.1-2019 · 45°

Reference a8691dd6fbb54e59/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 0.2 and cooling 35.4 kWh/m²; peak heating 8.6 and cooling 48.8 kW. Sensible heating is below 1 kWh/m² and is not judged. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-97.9-12.7705.118.697.912.7-33.3-4.1no
No simplification + Single zone building10.00-97.9-12.6705.118.597.912.6-33.2-3.9no
Perimeter core 3 m + Single zone building10.00-97.9-12.7705.018.697.912.7-32.9-4.1no
Perimeter core 4.57 m + Single zone building10.00-97.9-12.7705.018.697.912.7-32.7-4.0no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → a8691dd6fbb54e59/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → a8691dd6fbb54e59/R
  • Semantic merge + Stacked floor zone multiplier → a8691dd6fbb54e59/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

4A · 90.1-2007 · 0°

Reference 5a2fe0e00dd14e10/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 10.6 and cooling 54.4 kWh/m²; peak heating 122.4 and cooling 79.1 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-8.0-6.632.311.18.06.61.5-2.6no
No simplification + Single zone building10.00-8.0-6.632.311.18.06.61.5-2.6no
Perimeter core 3 m + Single zone building10.00-8.0-6.632.311.18.06.61.6-2.6no
Perimeter core 4.57 m + Single zone building10.00-8.0-6.632.311.18.06.61.6-2.6no
Perimeter core 3 m + Stack50.002.1-4.432.512.5-2.14.4-2.4-4.3no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 5a2fe0e00dd14e10/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 5a2fe0e00dd14e10/R
  • Semantic merge + Stacked floor zone multiplier → 5a2fe0e00dd14e10/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

4A · 90.1-2007 · 45°

Reference 49ceffa814366d2a/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 10.3 and cooling 50.3 kWh/m²; peak heating 117.8 and cooling 72.6 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-5.2-6.630.910.95.26.60.8-2.6no
No simplification + Single zone building10.00-5.2-6.630.910.95.26.60.8-2.6no
Perimeter core 3 m + Single zone building10.00-5.1-6.630.910.95.16.61.0-2.6no
Perimeter core 4.57 m + Single zone building10.00-5.1-6.630.910.85.16.61.0-2.6no
Perimeter core 3 m + Stack50.002.5-1.330.68.0-2.51.3-1.2-3.6no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 49ceffa814366d2a/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 49ceffa814366d2a/R
  • Semantic merge + Stacked floor zone multiplier → 49ceffa814366d2a/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

4A · 90.1-2019 · 0°

Reference 01377e52522925df/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 10.4 and cooling 44.2 kWh/m²; peak heating 76.9 and cooling 74.0 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-12.9-8.571.619.512.98.5-3.71.9no
No simplification + Single zone building10.00-12.9-8.571.619.512.98.5-3.71.9no
Perimeter core 3 m + Single zone building10.00-12.9-8.571.619.512.98.5-3.71.9no
Perimeter core 4.57 m + Single zone building10.00-12.9-8.571.619.512.98.5-3.71.9no
Perimeter core 3 m + Stack50.00-0.9-7.142.916.10.97.1-6.0-0.7no
Perimeter core 4.57 m + Stack50.00-1.7-7.437.214.71.77.42.40.0no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 01377e52522925df/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 01377e52522925df/R
  • Semantic merge + Stacked floor zone multiplier → 01377e52522925df/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

4A · 90.1-2019 · 45°

Reference 3d0a628d10cf1321/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 11.0 and cooling 39.9 kWh/m²; peak heating 75.8 and cooling 67.3 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-8.0-8.464.920.28.08.4-2.91.5no
No simplification + Single zone building10.00-8.0-8.364.920.28.08.3-2.91.6no
Perimeter core 3 m + Single zone building10.00-8.0-8.464.820.28.08.4-2.91.5no
Perimeter core 4.57 m + Single zone building10.00-8.0-8.464.820.28.08.4-2.91.5no
Perimeter core 3 m + Stack50.00-0.3-3.438.914.40.33.4-5.0-0.9no
Perimeter core 4.57 m + Stack50.00-0.8-4.930.813.60.84.92.70.1no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 3d0a628d10cf1321/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 3d0a628d10cf1321/R
  • Semantic merge + Stacked floor zone multiplier → 3d0a628d10cf1321/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

5A · 90.1-2007 · 0°

Reference c6aa70f0710149dd/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 21.9 and cooling 37.8 kWh/m²; peak heating 151.5 and cooling 73.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.001.2-3.815.715.6-1.23.8-0.2-5.4yes
Perimeter core 4.57 m + Stack50.000.4-5.511.414.9-0.45.5-0.0-3.7yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → c6aa70f0710149dd/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → c6aa70f0710149dd/R
  • Semantic merge + Stacked floor zone multiplier → c6aa70f0710149dd/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

5A · 90.1-2007 · 45°

Reference 364fdfe94d2a3ff9/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 20.5 and cooling 35.2 kWh/m²; peak heating 145.4 and cooling 66.9 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.001.5-0.615.09.5-1.50.6-0.3-3.9yes
Perimeter core 4.57 m + Stack50.000.9-3.210.410.9-0.93.2-0.1-3.0yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 364fdfe94d2a3ff9/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 364fdfe94d2a3ff9/R
  • Semantic merge + Stacked floor zone multiplier → 364fdfe94d2a3ff9/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

5A · 90.1-2019 · 0°

Reference e96b859edc1cda42/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 20.6 and cooling 30.6 kWh/m²; peak heating 92.0 and cooling 68.7 kW. Serial cost (R5): processor time 2.5 s, wall clock 2.6 s, peak committed memory 189 MiB, each the median of 3 repeats (processor-time CV 2.0 %); a zoning's ratios are its own medians over the reference's.

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %CPU ratioWall ratioMemory ratioMeets the threshold
Conditioned merge + Single zone building10.00-5.8-9.733.120.15.89.71.61.00.3560.3500.980no
No simplification + Single zone building10.00-5.7-9.733.120.15.79.71.61.10.5890.5990.989no
Perimeter core 3 m + Single zone building10.00-5.7-9.733.020.15.79.71.61.00.3990.3980.984no
Perimeter core 4.57 m + Single zone building10.00-5.7-9.733.020.15.79.71.61.00.3990.4140.982no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → e96b859edc1cda42/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → e96b859edc1cda42/R
  • Semantic merge + Stacked floor zone multiplier → e96b859edc1cda42/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

5A · 90.1-2019 · 45°

Reference 73566df2b2a28386/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 20.8 and cooling 27.4 kWh/m²; peak heating 89.1 and cooling 62.4 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Conditioned merge + Single zone building10.00-4.4-9.831.120.64.49.81.40.9no
No simplification + Single zone building10.00-4.4-9.731.120.54.49.71.41.0no
Perimeter core 3 m + Single zone building10.00-4.4-9.731.120.64.49.71.40.9no
Perimeter core 4.57 m + Single zone building10.00-4.4-9.731.120.64.49.71.40.9no
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 73566df2b2a28386/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 73566df2b2a28386/R
  • Semantic merge + Stacked floor zone multiplier → 73566df2b2a28386/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

7A · 90.1-2007 · 0°

Reference 8af2c9498f3d01f0/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 41.9 and cooling 34.1 kWh/m²; peak heating 184.1 and cooling 75.3 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.000.7-5.510.317.4-0.75.59.4-4.7yes
Perimeter core 4.57 m + Stack50.000.2-6.58.915.7-0.26.58.8-2.8yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 8af2c9498f3d01f0/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 8af2c9498f3d01f0/R
  • Semantic merge + Stacked floor zone multiplier → 8af2c9498f3d01f0/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

7A · 90.1-2007 · 45°

Reference cc9272588a055781/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 41.1 and cooling 30.5 kWh/m²; peak heating 190.3 and cooling 68.0 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.001.1-1.69.59.5-1.11.63.8-4.2yes
Perimeter core 4.57 m + Stack50.000.7-3.88.011.8-0.73.83.3-3.1yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → cc9272588a055781/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → cc9272588a055781/R
  • Semantic merge + Stacked floor zone multiplier → cc9272588a055781/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

7A · 90.1-2019 · 0°

Reference b9627d63b440ea0e/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 35.8 and cooling 24.9 kWh/m²; peak heating 118.8 and cooling 63.2 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.000.2-7.712.119.5-0.27.70.8-2.4yes
Perimeter core 4.57 m + Stack50.00-0.2-8.611.218.20.28.60.5-1.1yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → b9627d63b440ea0e/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → b9627d63b440ea0e/R
  • Semantic merge + Stacked floor zone multiplier → b9627d63b440ea0e/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

7A · 90.1-2019 · 45°

Reference 724ff1253ec4ca0a/R: No simplification + Stack, 5 zones, 2,294 m² conditioned; annual sensible heating 36.8 and cooling 21.2 kWh/m²; peak heating 117.7 and cooling 55.9 kW. This cell was not timed in the serial pass (R5).

ZoningZonesArea change %Heating error %Cooling error %Heating CV(RMSE) %Cooling CV(RMSE) %Heating NMBE %Cooling NMBE %Peak heating error %Peak cooling error %Meets the threshold
Perimeter core 3 m + Stack50.000.3-2.311.311.8-0.32.30.3-1.7yes
Perimeter core 4.57 m + Stack50.000.1-5.09.913.7-0.15.00.1-1.4yes
17 zonings write the same model as a listed one and are not shown
  • Conditioned merge + Single zone per floor type → Conditioned merge + Single zone building
  • Conditioned merge + Stack → Conditioned merge + Single zone building
  • Conditioned merge + Stacked floor zone multiplier → Conditioned merge + Single zone building
  • No simplification + Single zone per floor type → No simplification + Single zone building
  • No simplification + Stacked floor zone multiplier → 724ff1253ec4ca0a/R
  • Perimeter core 3 m + Single zone per floor type → Perimeter core 3 m + Single zone building
  • Perimeter core 3 m + Stacked floor zone multiplier → Perimeter core 3 m + Stack
  • Perimeter core 4.57 m + Single zone per floor type → Perimeter core 4.57 m + Single zone building
  • Perimeter core 4.57 m + Stacked floor zone multiplier → Perimeter core 4.57 m + Stack
  • Semantic merge + Single zone building → No simplification + Single zone building
  • Semantic merge + Single zone per floor type → No simplification + Single zone building
  • Semantic merge + Stack → 724ff1253ec4ca0a/R
  • Semantic merge + Stacked floor zone multiplier → 724ff1253ec4ca0a/R
  • Single zone per floor + Single zone building → Conditioned merge + Single zone building
  • Single zone per floor + Single zone per floor type → Conditioned merge + Single zone building
  • Single zone per floor + Stack → Conditioned merge + Single zone building
  • Single zone per floor + Stacked floor zone multiplier → Conditioned merge + Single zone building

Atlas programs

The atlas programs each program key of the prototype takes, as the suite's saved inputs name them (release 2.4.0 IDs); the prototype's geometry and glazing are BEMGen's DOE record. Method and caveats.