DOE layout records and the grid plan layout

Status: Accepted (stages P0a and P5a of the DOE geometry design note; the owner, with PR #1, D-176) · Code: src/Lod.Generators/Doe/, scripts/doe-geometry/, the harness in tests/Lod.Generators.Tests/Doe/Harness/ · Data: src/Lod.Generators/Doe/Layouts/*.json, tests/fixtures/doe/*.answer.json

Stage P0a lays the foundation the DOE generator families (P1 to P6) build on: the layout of every non-apartment DOE type as data, a shared layout block that turns a storey of that data into a plan, the S3 size rule, program keys with the program map, and a harness that compares a generated model with the source figures. It adds no generator and no Grasshopper component; those came with the family stages (below).

Layout records

One record per type, fifteen in all: small-office, medium-office, large-office, full-service-restaurant, quick-service-restaurant, strip-mall, stand-alone-retail, supermarket, warehouse, primary-school, secondary-school, small-hotel, large-hotel, hospital, outpatient (the note's "14" counted one fewer; its §4 table lists these fifteen). scripts/doe-geometry/extract.py writes them from the DOE reference buildings and openstudio-standards (its README (scripts/doe-geometry/README.md)); they are embedded in Lod.Generators and loaded with DoeLayoutRecords.Load(DoeBuildingType), which checks the format and fails with an InvalidDataException naming the record and the reason. Lod.Generators reads them with its own small JSON reader (DoeJson), since it depends on Lod.Core only.

Field Meaning
type, sources the record's name; each source file with its role and SHA-256 (the reference IDF, the openstudio-standards OSM, and the prototype inputs that name it)
gaps, gapConventions the gaps G1–G5 that apply (S7), found from the data
sourceCeilingHeight the zone height under a plenum where G1 applies (S6: 2.7432 m in the medium office, 2.744 m in the large office)
planOrigin the source coordinates of the plan origin, the building's south-west corner over all storeys
storeys bottom-up: elevation (the source's), floorHeight (zone and plenum, G1), multiplier (the large office's x10 floor, the large hotel's x4 floor), xCuts, yCuts, zones
zone id, name (the source zone's), programKey (standards space type), standardsBuildingType, programKeyLink (the rule that linked the key: office_room, spc_typ, osm_space, osm_tiling, osm_space_2013), programKeySpaces (the OSM spaces the rule used), programKeySource (the file it read, with its SHA-256), multiplier within the storey (hospital and large-hotel rooms; carried onto the planned zone since P5a, S8), cells (rectangles [x0, y0, x1, y1) of cell indices), and for a zone under G4 gap and, when it is repeated on a storey it spans, sourceStorey
programGlazingRule, programGlazing since format version 2 (stage P7): every program key of the record once, in ordinal order, with the source's WWR per orientation (N, E, S, W) and skylight ratio and their basis: true_outdoor_wall (the answer key's per-key inputs, below), office_reference (the office reference ratio of every orientation, officeGlazing), gap_source_wall (every zone of the key under a gap: the same true-outdoor-wall rule with the gap zones and orientations counted, and the skylight over the source roof, from the source only), or interior (no counted outdoor wall or roof, no ratio); null where the key has no counted wall of that orientation or no counted roof. The loader checks the keys against the zones, each ratio in [0, 1), and the basis against the ratios (an interior key has none, every other key one at least); DoeProgramPresets reads it
notices the DOE credit (a US government work, public domain, attribution requested) and the openstudio-standards BSD-3 licence

The offices take their rooms from the openstudio-standards detailed offices on the reference plates and elevations (O6, O8): the large office's storeys stand at 0, 19.816 (x10), and 43.5952 m, not at the OSM's 16.77 and 33.54 m, and keep their data-centre zones. Every other type takes its zones from the reference IDF. Zones per storey (source zones; the outpatient's upper storeys add four G4 copies): small office 17; medium office 23/21/21; large office 26/26/26; restaurants 2; strip mall 10; stand-alone retail 5; supermarket 6; warehouse 3; primary school 25; secondary school 25/21; small hotel 19/16/16/16; large hotel 7/7/7; hospital 9/11/13/13/8; outpatient 59/37/22, the note's figures. The outpatient record therefore has 59/41/26 zones per storey: the note's 59/37/22 plus, on each upper storey, the copies of the three stairs (north-east, north-west, south-west) and the lift that span all three storeys (G4).

The record tests check the elevations, floor heights, and multipliers against figures from the same extraction and the note; from P1 on, each generator stage checks them against its own parameters as well (T1 through the harness).

The generator families

Eleven generators build the fifteen records (design note §4). Each family document states its parameters, limits, gaps, source facts, and acceptance results, and doe-components.md the Grasshopper components, their icons, and the program map.

Generator Records Family document
RingOfficeGenerator small-office, medium-office, large-office doe-ring-office.md
RestaurantGenerator full-service-restaurant, quick-service-restaurant doe-single-storey.md
StoreRowGenerator strip-mall doe-single-storey.md
RetailBoxGenerator stand-alone-retail doe-single-storey.md
SupermarketGenerator supermarket doe-single-storey.md
WarehouseGenerator warehouse doe-single-storey.md
SchoolGenerator primary-school, secondary-school doe-school.md
CorridorHotelGenerator small-hotel doe-corridor-hotel.md
TowerHotelGenerator large-hotel doe-tower-hotel.md
HospitalGenerator hospital doe-hospital.md
OutpatientGenerator outpatient doe-outpatient.md

The grid plan layout

GridPlanLayout.Layout(xCuts, yCuts, zones) (internal, S1) lays out a storey: every zone is a union of grid cells, cells in no zone lie outside the footprint, and the footprint is the union of every zone's cells, so outlines that are not rectangles and footprints with holes (a court, the gaps left by multiplied rooms) come out of the cells alone. Each polygon is traced exactly from its cells' edges on the cut coordinates, with collinear vertices dropped; where two rings meet at a vertex the tracing turns most to the left, so cells touching only at a corner stay apart. A boundary that still passes one vertex twice, such as a court that touches the outline at a corner, is split there into simple rings, so the court is a hole of its own that shares that vertex with the outer ring (and the surface builder takes it as it takes any hole). It returns a PlanLayout of PlannedZones with their program keys, or errors: DuplicateZoneId (two zones with one ID), InvalidParameter (cuts that do not increase, a zone without cells, cells outside the grid), OverlappingZones (a cell in two zones), DisconnectedGroup (a zone that is not one polygon), and NotSupported (a footprint that is not one polygon). DoeStoreyRecord.Layout() lays out a record storey at its default size.

Multiplied rooms (P5a, S8, ADR-026). Each zone carries its record multiplier onto its PlannedZone (below 1 is InvalidParameter). On a storey with a multiplied zone, every cell of the grid is in the footprint: the cells no zone holds are the copy space, where the undrawn copies of the multiplied rooms stand (O5). The drawn zones may then be several polygons on one plate, as on the hospital's ground storey, whose ER_Trauma2_Flr_1 stands apart from the rest with the copies of the ×4 triage and exam rooms between them. The rule is the sources': on every storey of the hospital and the large hotel, every wall of a zone toward an empty cell is a self-referencing Surface in the reference IDF (its selfAdjacentWallLength in the answer key). The surface builder makes those walls, and every wall between zones of different multipliers, SelfAdjacent. A storey without a multiplied zone keeps the rule above: cells in no zone lie outside the footprint, and a footprint of several polygons is NotSupported.

Size variation (S3)

GridAxis is one axis of a building's grid: the union of its storeys' cuts (GridAxis.Union), so a coordinate several storeys share moves alike on all of them (Map), and one flag per interval, fixed or flexible (WithFixed). Resize(length, parameter, tolerances) keeps fixed intervals and shares the change among the flexible ones in proportion to their slack, their default length less 1 m (GridAxis.MinimumFlexibleInterval), when the axis shrinks and when it grows (S3 as amended in stage P1, decided above the controller; P0a shared it by default length). Every flexible interval therefore reaches 1 m at the same length, the shortest valid one (MinimumLength: the fixed intervals plus 1 m per flexible interval, or its own length under 1 m); an interval of 1 m or less has no slack and keeps its length, which replaces P0a's rule that such an interval may grow but not shrink. A length within ToleranceSettings.Distance of the default is the default (the same axis), so the defaults stay exact. A length shorter than MinimumLength (by more than the distance tolerance), any other length of an axis whose flexible intervals have no slack (a total slack within the distance tolerance counts as none), and any other length of an axis without flexible intervals are InvalidParameter. Which intervals are fixed (perimeter depth, corridor width, room bay) is each family's choice; repeated units (store counts, room bays, wings) are left to the families as well. A fixed band that a family's size parameter sets (a corridor width, a perimeter depth) must be at least GridAxis.MinimumFixedBand, 0.5 m (the controller's minor parameter limit under D-098, stage P1); each family checks its own bands and reports a narrower one as InvalidParameter. The minimum applies per band a parameter sets, a side's whole band (the large office's south perimeter of 5.486, 0.610, and 6.066 m intervals is one band), not to each grid interval within it; later families apply it the same way.

Program keys and the program map (S4)

A zone's ProgramKey is the standards space type from source data, never parsed from a zone name (D-061). For the offices it is each OSM room's standards space type (MediumOffice - OpenOffice, link office_room). For every other type the extraction applies the controller's rules in order, and each zone records the rule, the OSM spaces it used, and the file it read with its SHA-256:

  1. spc_typ: the zone's name equals a standards space type of the OSM's standards building type in the pinned doe_ref_1980_2004.spc_typ.json (both restaurants, the supermarket's six zones, the warehouse's office, the stand-alone retail's back space);
  2. osm_space: the geometry OSM that doe_ref_1980_2004.prototype_inputs.json names for the DOE Ref 1980-2004 template has a space of the zone's name, and the key is that space's standards space type; the floor areas are not part of the rule, and a difference above 0.1 m² would be recorded (programKeyAreaMismatch) and reported, of which there is none;
  3. osm_tiling: OSM spaces of exactly one standards space type tile the zone, their union equal to its floor within the ADR-004 distance tolerance and their summed area to its area within the relative area tolerance (the warehouse's bulk and fine storage);
  4. otherwise the extraction stops with exit code 2 and a message naming the type and the zone; no zone of any record is one.

The record's skylights are its New2004 source's (the schools' gyms). An atlas family's skylights come from that family's source geometry instead (Doe/Skylights/family-skylights.json, D-249, ADR-039). The same file holds each skylit key's source layouts, one per skylight ratio, the record's included (D-252): the retail, warehouse, supermarket, and school generators give a zone whose preset has a source's ratio that source's count, size, and places of skylights, scaled to the zone's roof (design note).

Since D-246 (the owner's G1) the stand-alone retail's Core_Retail and Front_Retail, both Retail by rule 2, are keyed by the spaces of their names in the 90.1-2013 geometry openstudio-standards names for the type (ASHRAE9012013RetailStandalone.osm, link osm_space_2013): the keys Core_Retail and Front_Retail, each with its own glazing (the front's south windows are the front's). The atlas's DOE Ref and 90.1-2007 families give both their one Retail program through the crosswalk (DOE components).

The OSM only names the type; the geometry stays the reference's (O8). Every zone of the fifteen records has a key. Programs for these keys come from the atlas (A1), which is not yet checked here.

DoeSpaceTypes.Of(key) is the fixed table from key to BEMGen SpaceType, by whole key, unmapped keys Other: offices (OpenOffice, ClosedOffice, Office, the small and medium office variants) Office; corridors (Corridor, Corridor2, Hall, Hall_infil) Corridor; Stair; Lobby and Entry; Mechanical and Elec/MechRoom; Kitchen; Dining, Cafeteria, Cafe; retail and the strip-mall stores Retail; OR OperatingTheatre; restrooms, toilets, storage, janitor, and locker rooms Service; Gym, Gym - audience, Auditorium ActivityHall. No key is a DwellingUnit. DoeProgramMap is the presets record of the DOE generators: one preset per key, a slot per key of the table's space type (a typed preset must have it, an any-program preset fits every key), a zone's preset found by its key (PlanPresets.PresetFor), a key without a preset MissingPreset.

Answer keys and the comparison harness

Every type has an answer key, tests/fixtures/doe/<type>.answer.json, with every quantity of the note's §5 T1–T4 (and T7 for the offices) as BEMGen builds it under the gap conventions, computed from the source polygons independently of the record's grid: storey count, elevations, floor heights, multipliers, and outlines (T1); per storey the zones with their program keys, floor areas, and outdoor wall lengths per orientation, and the walls each pair of zones shares (T2); the floor area in total and per program key, with the source value and the adjustments between them (T3); the window and skylight areas with the source's WWR per orientation and skylight ratio per zone, the T4 program inputs (T4); the reference's perimeter-core areas and depth (T7).

Office T4 inputs (the controller's decision, a test fixture until the atlas gives WWR per orientation, A2): each office room's WWR per orientation is the reference's glazing of that orientation, windows and glass doors as the note's §5 figures count them, over the reference's outdoor wall area of that orientation: in the medium and large offices the conditioned zones' walls, below the 2.74 m source ceiling height (S6), in the small office, which has no plenum, the full 3.05 m walls. It applies to every room facing that orientation, on its walls at that height, so the rooms' glazing adds up to the reference's: small office 16.73, 11.16, 20.64, and 11.16 m² (north, east, south, west; the south includes the 3.91 m² glass door), medium office 195.85 and 130.57 m², large office 1,390.85 and 927.23 m². The answer key keeps the ratios, the height, and the reference figures (officeGlazing), each room's wall area at that height (glazingWallArea), and the detailed office's own windows (roomsWindowArea; the small office's has no door, 16.73 m² south).

The harness (DoeComparison in Lod.Generators.Tests) compares a generated plan or floor per storey with an answer key and reports every quantity as a finding, with the tolerances of ToleranceSettings.Acceptance (ADR-004): 0.01 m for T1, 0.1 m² and 0.05 m for T2, 0.1 % for T3, 1 % for T4, and 0.1 m² for T7. A quantity of a zone the key marks with a gap (G4), and floor heights under G5, are reported as excluded, not failed, and the T4 building totals leave the same zones out on both sides (the key's source glazing of those zones and the generated glazing of them), so the secondary school's tall zones and the outpatient's stair and lift copies do not fail the totals. Since P0b the harness measures skylights through a callback; DoeGlazingAcceptanceTests measures them on the roofs of Stack of the storeys, so a covered ceiling counts none.

Every record, rendered through GridPlanLayout at its defaults with fixture programs, matches its answer key on T1, T2, and T3, the hospital's ground storey and T3 total included since P5a. On a storey with multiplied rooms T1 compares the drawn outline, the union of the zones, which the key records, not the footprint, which holds the copy space too. T2 splits the key's walls on no other zone into the self-adjacent walls toward the copy space (selfAdjacentWallLength, compared with the walls the layout makes self-adjacent and that no other zone's wall stands against) and the outdoor rest, and counts the walls two zones of different multipliers share back to back as shared, as the key does. Perimeter Core at the reference's perimeter depth gives the reference's five zones per storey of the three offices within 0.1 m² (T7).

T4 (P0b, on the generators' path since P5a). DoeGlazingAcceptanceTests lays out every record with one program per program key, the DoeProgramMap the DOE generators take, each with its key's WWR per orientation and skylight ratio from the answer key (programGlazing, the atlas input A2), the record's sourceCeilingHeight as the glazing reference height where G1 applies (S6), and compares with the key within 1 %: window area in total per orientation and per program key and orientation, skylight area in total and per key, and window and skylight area per zone where every zone of the key shares its ratio.

  • Per-key inputs (programGlazing, P5a, decided by the session above the controller). For each program key and orientation, the source glazing over the wall it is a ratio of (the true outdoor wall; under G1 the wall below the source ceiling, glazingWallArea), each summed over the key's zones times their storey's and own multipliers, without the zones and orientations under a gap; the skylight ratio is the skylight area over the source roof area on the same rule. A key whose every zone is under a gap has none, and the harness gives it no glazing.
  • Zones whose ratio differs from their key's (glazingRatioDifferences): every zone and orientation (roof for skylights) where the key's ratio times the zone's wall misses the zone's source glazing by more than T4's 1 % (GLAZING_RELATIVE, ADR-004 Acceptance.RelativeGlazingArea, as ToleranceSettings.RelativeEquals reads it). Their per-zone quantities are reported, not failed (reported: the zone's ratio differs from its program key's), and a test checks that the list is exact: each listed quantity misses the source, every other passes. Per record: small hotel 43 (GuestRoom206_208 S 0.1908 against its key's 0.1578, and its floors' repeats), outpatient 38, hospital 6, every other record 0. The key totals count every zone, so they still match.

  • Basis (review rounds 2 and 3, A). A zone's WWR of an orientation is its source glazing over its true outdoor wall: its source walls marked Outdoors less every stretch that coincides with a wall of another zone on the same plane, back to back, whatever that wall's boundary, since a stretch with a zone on its other side is not outside (the façade-line test of D-041 within the ADR-004 distance and angle tolerances, COINCIDE_DISTANCE and COINCIDE_ANGLE of extract.py). A stretch counts over the height both walls share: its area is the plan overlap times the height overlap, its length that area over the zone wall's height. extract.py computes it from the source only (trueOutdoorWallLength, trueOutdoorWallArea per zone) and lists every stretch in the key (coincidingOutdoorWalls: storey, zone, partner, orientation, length, area, and the partner wall's boundary class partnerBoundary: Outdoors, Surface paired, Surface self-referencing, or other). Since P5a a stretch of a wall not marked Outdoors with no zone behind it is a true outdoor wall too, whatever its source boundary (geometry decides, as D-162), unless it faces the copy space of a multiplied room (selfAdjacentWallLength, the rule of GridPlanLayout, read PROBE = 0.01 m outside the stretch); the key lists each with its source boundary (nonOutdoorExteriorWalls). For the offices the reference basis is reduced the same way (officeGlazing.referenceCoincidingWalls). T2 checks the true outdoor wall per zone and orientation against what BEMGen draws (true outdoor wall), where the two meet; every record passes it. The partners are the counted zones only: plenums, attics, and basements are left out, consistent with G1; a probe found no stretch against them in the fifteen reference files and the three office OSMs.

  • Stretches found: 18. Outdoors: 8, all in the secondary school (each bathroom and main corridor against the tall auditorium, 11 m and 15 m, both ways). Surface paired: 2, the small office's Corridor_1 against the lobby (south, 0.544 m) and the large office's Lobby_Bot_ZN_2 against Corridor_Bot_ZN_1 (west, 0.049 m). Surface self-referencing: 8, the outpatient's Floor_2_Reception_Hall against eight rooms (south, 26.518 m of its 28.651 m). Other: none. The eleven other records have none.
  • Source boundary artifacts. The stretches against a non-Outdoors wall are walls the source exposes to outdoor air although a zone adjoins them, such as the outpatient reception hall's 26.5 m of south wall against the X-ray and exam rooms; BEMGen draws them between the zones. An energy comparison with the source must know that these walls differ. P5a (ADR-026) does not change them, and keeps the source's self-referencing walls between zones of equal multiplier (the outpatient's) as shared Interzone walls; SelfAdjacent is only for multiplied rooms.
  • Excluded, not failed: zones under a gap and, per orientation, walls against a tall zone (G4) drawn on its own storey only (gapOrientations: five first-floor zones of the secondary school, against its tall auditorium and gyms); the warehouse's office (G4, under the fine-storage floor the storey height drops) and fine storage (its dropped floor); nothing else since P5a. The orientations with self-adjacent source walls toward multiplied rooms (selfAdjacentWallLength), pending S8 and P5a until then, are compared: in T4 the large hotel's 8 and the hospital's 58 quantities (46 before, without the ground storey) all agree, the large hotel's corridors included, whose walls toward the ×19 and ×9 rooms are self-adjacent and so take no glazing; in T2 their true outdoor walls agree too, and the hospital's ground storey and totals are compared and pass (DoeGlazingAcceptanceTests).
  • Walls on nothing that the source does not mark Outdoors (P5a). Over the fifteen records there is one: the hospital's OR_NurseSat_Flr_2_Wall_1_East, 16.764 m of the plate's east façade (x = 70.104 m, y from 0 to 16.764 m), a self-referencing Surface in the reference IDF, so the source treats it as adiabatic, although no zone and no copy stands beyond it. Geometry decides: it is a true outdoor wall of OR_NurseStn_Lobby_Flr_2 in the key, BEMGen draws it outdoors, and T2 agrees. An energy comparison with the source must name it.
  • Roofs and exposed floors per zone (P5a). T2 compares, for the hospital and the large hotel, each zone's roof and exposed floor area on Stack of the storeys with the key's sourceRoofArea and sourceExposedFloorArea within 0.1 m²; a floor or ceiling on the copy space of the storey below or above is neither. Without the copy space the check fails for both records.
  • Result: every record passes T4 on every compared quantity, the secondary school's bathrooms included, and the primary school's 13.38 m² of skylights per zone and in total. The secondary school's skylit zones are its G4 gyms, which the totals leave out.

Source facts reported

  • The large office's 46,320 m² of the note (§5 P1, "above grade") includes the basement: above grade it is 42,757.25 m² (12 plates of 3,563.1 m²), and the basement (G3) adds 3,563.1 m².
  • T7 runs at the reference's exact perimeter depth, the core's mean inset: 5.0 m (small office), 4.5733 m (medium), and 4.5732 m (large), which the note rounds to 4.57 m; at 4.57 m the cores differ from the reference's by 0.43 and 0.65 m², outside T7's 0.1 m².
  • The small office has no plenum, so G1 does not apply to it (the note's §4 lists G1 for every office); its gaps are G2 only.
  • The small office's detailed rooms have no glass door, so their own south glazing is 16.73 m², not the reference's 20.64 m²; the office T4 inputs above take the reference's ratio, glass door included, so T4 reproduces 20.64 m² without a looser check.
  • The outpatient has 59/41/26 zones per storey in its record: the note's 59/37/22 plus the G4 copies of its stairs and lift.
  • The hospital's fifth storey has two zones that overlap by 2 mm in the source; the extraction puts their edges on one cut (an area change of 0.018 m², recorded as an adjustment).