Program Presets

Status: Current as of S8.8 (v0.8.7) · Date: 2026-10-02 · Decisions: D-009, D-024, D-026, D-038, D-039, D-047, D-061, D-079, D-094, D-097, D-108, D-124, D-126; ADR-014, ADR-017 (infiltration is an envelope input; mixed presets, §6), ADR-018 (the extended program: §1.3; atlas programs from program JSON, §7), D-172 and ADR-027 (program JSON 5.4.0 of atlas release 2.0.0: daylighting controls and water mains inlets, §1.3, §6.2, §7)

Read this first: the presets that ship with BEMGen (ExampleResidentialPresets and, since S8.4, ExampleNonResidentialPresets) hold illustrative round numbers chosen for development and tests, and which of them are conditioned is an illustrative choice too. They are NOT taken from the DOE prototype buildings or from any standard. Sourced presets are an open research input (§3). The defaults of the heat fractions, the occupants' activity, and the water temperatures (§1.3) are the IDF writer's old fixed values, not sourced ones either. Presets made from the atlas's program JSON (§7) are different: their values are the atlas's.

A program preset describes the energy-relevant program of one space type. This document defines what a preset contains, lists the example presets and their values, records how S1 deviates from the original plan for sourced values, states which prototype assumptions BEMGen deliberately does not reproduce, and explains how to build custom presets.

1. What a program preset is

A program preset carries everything BEMGen assigns to a space of one type: its loads with their schedules, whether it is conditioned and, if so, its heating and cooling setpoints, and its window parameter (D-024, D-038). Since the program JSON stage (D-126) it also carries the heat fractions of its power loads, the heat properties of its occupants, the temperatures of its hot water, and the calendar its schedules were expanded on (§1.3). There is one preset per space type. Rooms are never modelled: at the most detailed level (Z0) a dwelling unit is one zone per storey (D-009, D-085), and a non-residential floor has one zone per department, a contiguous group of rooms of one program (D-097, ADR-014).

In code a preset is a ProgramPreset (src/Lod.Core/Programs/ProgramPreset.cs):

Member Meaning Rejected with diagnostic
Name Display name; descriptive only: it appears in reports, provenance, and messages and is never used for matching (D-061) EmptyName when empty or white space
SpaceType The space type the preset applies to: DwellingUnit, Corridor, Stair, Core, Lobby, Service, Mechanical, Other, and since S8.4 the non-residential types Office, Retail, Mall, Kitchen, Dining, OperatingTheatre, CleanCorridor, DirtyCorridor, ClinicalSupport, CareBedroom, CareCommunal, and ActivityHall (ADR-014). (Mixed denotes a simplified zone that combines several space types.) —
Program A ZoneProgram: at most one load per load type, end use, and basis, each with a fraction schedule; the occupants' PeopleProperties; a Thermostat (a heating setpoint schedule, a cooling setpoint schedule, or both, in °C) for a conditioned space, or no thermostat for an unconditioned one; the calendar its schedules were expanded on, if any (§1.1 to §1.3) see §1.1
WindowToWallRatio Window-to-wall ratio, the single window parameter (D-026) WindowToWallRatio when outside [0, 1)
Source Provenance of the values (D-124, D-126): null for a preset built from plain values, such as the examples; for a mix, the record of its inputs (§6.4); for a program JSON, the JSON's identity and checksum, its source program, the calendar, every override, and what was left out (§7) —
Calendar The calendar the program's schedules were expanded on (Program.Calendar, §1.3); null for BEMGen's own presets —

A plan generator takes one preset per space type it places, as a typed record (D-061): the linear plan generator takes LinearPlanPresets(DwellingUnit, Corridor, Stair), and in Grasshopper the Linear Plan Generator has the three required inputs Dwelling Unit, Corridor, and Stair. A preset whose space type differs from its input's is an error (PresetSpaceTypeMismatch); each zone gets the preset of its space type. An any-program preset (S8.8, D-108) has no space type (SpaceType is null): preset.AsAnyProgram() returns any preset without its space type and with every other value unchanged, and every input of every generator accepts it; the zones keep the input's space type, take the preset's program and WWR, and the plan's provenance records AnyProgramPreset.<Input>=<name>. (Until S4.1 presets were passed as a ProgramPresetSet, a list with at most one preset per space type.)

A preset can also be described by its plain values, PresetValues: name, space type, WWR, Conditioned, the switches HeatingOn and CoolingOn (default true), constant heating and cooling setpoints (°C), and loads (PresetLoadValue: type, basis, value, fraction schedule). PresetValues.ToPreset() builds the ProgramPreset; for a conditioned preset the setpoint schedules are constant temperature schedules named "{Name} Heating Setpoint" and "{Name} Cooling Setpoint", one for each side that is on (a conditioned preset with both sides off is NoSetpoint), and for an unconditioned preset the setpoints are ignored. Every invalid value is reported at once, with the diagnostics of §1.1.

Windows. Walls carry explicit windows (D-039). The S2 linear plan generator uses the preset's WWR for one simple rule: one window centred on each outdoor wall of a zone, with area = WWR × wall area (D-026). Where zones are merged and walls are rebuilt, each outdoor wall gets one window centred on it with the glazed area of the source windows it covers, shaped by the same rule, so the preset's glazing is conserved per wall, façade, orientation, and building (D-079, S5).

1.1 Loads, bases, and schedules

A load is a LoadDefinition: a LoadType, an end use (a non-empty text, by default the type's snake-case name, §1.3), a LoadBasis, a non-negative design value expressed per that basis, and a fraction schedule; lighting and equipment loads also carry heat fractions and hot-water loads their temperatures (§1.3). Its design magnitude is value × basis quantity, and its scheduled magnitude at hour t is design magnitude × s(t) (ADR-007).

LoadType Design magnitude
Occupancy people
Lighting W
ElectricEquipment W
GasEquipment W
DomesticHotWater m³/h (peak flow)
Ventilation m³/h

Infiltration is not a program property (D-124, ADR-017). Its magnitude follows the envelope (a zone's exterior surface area or volume), which a preset does not know, so it is an input of the envelope preset applied to every zone at conversion. LoadType.Infiltration and LoadBasis.PerExteriorWallArea no longer exist, and a load type or basis that is not defined is rejected (UndefinedLoadKind).

LoadBasis Value is expressed per Basis quantity of a zone Example value units
PerFloorArea m² of floor area floor area, m² W/m², people/m²
PerPerson occupant design occupants (the summed magnitude of the zone's occupancy loads) m³/h per person
Absolute zone 1 W, people
AirChangesPerHour zone air volume per hour volume, m³ 1/h
PerDwellingUnit (D-126) dwelling the zone's dwelling count: 1 for a generated dwelling-unit zone, 0 for any other zone, Σ fᵢ·Nᵢ of its sources for a merged zone (fractional after a split) W/dwelling, people/dwelling

Validation, with the diagnostic code each rule raises:

  • A load type and a basis must be defined (UndefinedLoadKind, D-124).
  • A load value must be finite and non-negative (LoadValue).
  • Occupancy is expressed only PerFloorArea, Absolute, or PerDwellingUnit (LoadBasisNotAllowed).
  • An end use, when given, must not be empty (EmptyName).
  • A load needs a fraction schedule (ScheduleKindMismatch); a thermostat's setpoints need temperature schedules (ScheduleKindMismatch, from Thermostat.Create).
  • A program has at most one load per load type, end use, and basis (DuplicateLoadType; D-047 said type and basis, D-126 adds the end use). A load type may appear in several bases, for example ventilation per person plus per floor area, and in several end uses, for example lighting and additional lighting; these components add up.
  • Heat fractions are given only for lighting and equipment loads, each in [0, 1] (HeatFractionValue), summing to at most 1 (HeatFractionsExceedOne), with no non-zero value in a field the EnergyPlus object lacks (HeatFractionNotSupported); water temperatures only for hot-water loads (WaterTemperaturesNotAllowed), the target never below the inlet (WaterTargetBelowInlet).
  • A zone with a per-dwelling load must have dwellings (PerDwellingWithoutDwellings, raised at plan generation and by validation): give a per-dwelling preset to dwelling-unit zones only, or express the load per floor area.
  • A per-person load needs an occupancy load in the same program (PerPersonWithoutOccupancy).

Schedules hold 8760 hourly values for a non-leap year (ADR-003). A Fraction schedule's values lie in [0, 1]; a Temperature schedule holds finite values in °C (setpoints and hot-water temperatures); an Activity schedule (D-126) holds finite values of at least 0 in W per person. Schedule.FromDailyProfiles builds a year from one 24-hour weekday profile (Monday to Friday) and one weekend profile (Saturday and Sunday), given the weekday of 1 January; this factory does not model holidays. A program JSON expands its rule-based schedules on a calendar that has holidays (§7).

1.2 Conditioning

Conditioning comes from the program preset (D-038). A preset whose program has a Thermostat is conditioned, with the thermostat's heating setpoint schedule, its cooling setpoint schedule, or both (since D-126 each side is optional, at least one is needed, and where both exist the heating setpoint never exceeds the cooling setpoint at any hour, SetpointsCross); a preset without one is unconditioned and has no setpoints (ZoneProgram.IsConditioned is false).

When a plan simplifier merges zones, the merged zone is conditioned if any source contributing floor area to it is conditioned ("any conditioned wins"). Its setpoints are floor-area weighted over the conditioned sources only, T*(t) = Σ wᵢTᵢ(t) / Σ wᵢ with wᵢ the transferred floor area of conditioned source i: a prescribed control rule, not a conservation invariant (ADR-005). A mix of presets follows the same rule with the user's weights in place of areas (§6). Merging conditioned and unconditioned spaces can therefore enlarge the conditioned floor area; from S3 on, validation reports that change without enforcing it, because it is a consequence of the zoning simplification under study (D-038).

Since D-126 each side is merged on its own. Heating is on in the merged zone when any source contributing floor area heats, and its setpoint is floor-area weighted over those sources only; cooling likewise over the sources that cool. A merged zone whose heating setpoint would exceed its cooling setpoint at any hour is an error (SetpointsCross) that names the sources, because EnergyPlus rejects crossed setpoints; merge zones whose setpoints are compatible.

1.3 Heat fractions, people, hot-water temperatures, and the calendar (D-126)

The atlas's program contract describes more of a program than loads and setpoints, and a program that ignored the rest would replace the atlas's assumptions with BEMGen's silently. The program therefore holds the properties below (ADR-018). Each default is the value the IDF writer always used, so a preset that sets none of them behaves as before. Like the example loads, the defaults are writer defaults, not values from a standard or a prototype.

Property Held by Rule Default
End use each load a non-empty text; it tells loads of one type apart the type's snake-case name: occupancy, lighting, electric_equipment, gas_equipment, hot_water, ventilation
Heat fractions: radiant, latent, lost, visible, return air lighting, electric equipment, and gas equipment loads only each in [0, 1]; the sum is at most 1 within ToleranceSettings.AbsoluteFraction (1e-9); the convective fraction is what remains. A non-zero latent or lost fraction on lighting, or visible or return-air fraction on equipment, is an error: the EnergyPlus object has no such field lighting: radiant 0.42, visible 0.18; electric equipment: radiant 0.5; gas equipment: radiant 0.3; every other fraction 0
Activity level the program (its occupants) an hourly Activity schedule, W per person, not negative constant 120 W per person, named BEMGen Activity Level
Radiant fraction of people the program in [0, 1], of the occupants' sensible heat 0.3
Sensible fraction of people the program a number in [0, 1], or autocalculate, which lets EnergyPlus compute it autocalculate
Heating and cooling setpoints the thermostat each side optional, at least one (§1.2) —
Hot-water target and inlet temperatures domestic hot-water loads only hourly Temperature schedules, °C, the target never below the inlet by more than AbsoluteSchedule; since D-172 the inlet may instead be the water mains temperature EnergyPlus correlates from the weather file (InletFromWeatherFile, no schedule, so no hourly check) constant 60 °C and 10 °C, named BEMGen Hot Water Target Temperature and BEMGen Hot Water Inlet Temperature
Daylighting controls (D-172) the program the controlled share of the program's lighting power in [0, 1], an illuminance setpoint (lux, positive), a control type (continuous, stepped, continuous off), a method (split flux, DElight), minimum input power and light output fractions in [0, 1], at least one step (DaylightingValue) none: BEMGen's own presets have no controls
Calendar the program a non-leap year and its distinct holidays; programs combined in a merge, a mix, or a building must share it (CalendarMismatch) none: BEMGen's own presets record no calendar and assume a year whose 1 January is a Monday

A program without a calendar agrees only with a calendar whose 1 January is a Monday (2007 is the default year). The heat fractions, activity, and fractions of people, and the water temperatures, appear in the IDF as the fields of Lights, ElectricEquipment, GasEquipment, People, and WaterUse:Equipment (convert2idf.md); the calendar sets the run period's year. Water adds no heat to a zone in the IDF (the contract keeps plant and zone gains separate); the temperatures define the water heat the load stands for, flow × (target − inlet), which the aggregation conserves.

How these properties combine when zones or presets are merged is in the research brief, §7 and in §6.2 for a mix.

2. Example presets

The values below, and the choice of which spaces are conditioned, are illustrative and chosen for development and tests. They are NOT taken from the DOE prototype buildings, from any standard, or from measured data. Do not use them as research inputs, and do not present results obtained with them as representative of any prototype or real building.

The example presets take the defaults of §1.3 for their end uses, heat fractions, activity, people fractions, and water temperatures, and have no calendar.

2.1 Residential presets

src/Lod.Core/Programs/ExampleResidentialPresets.cs defines one preset for each space type that the S2 linear plan generator places: dwelling unit, corridor, and stair, each as PresetValues (DwellingUnitValues, CorridorValues, StairValues) and as the preset built from them (DwellingUnit, Corridor, Stair). The Grasshopper components Dwelling Unit Preset, Corridor Preset, and Stair Preset use these values as the defaults of their inputs (§5). Tests in S1 and in later stages use these presets, so changing a value changes test expectations and snapshots.

Preset (Name) Space type Conditioning Heating setpoint Cooling setpoint WWR
Example Dwelling Unit DwellingUnit conditioned 21 °C, constant (Example Dwelling Unit Heating Setpoint) 24 °C, constant (Example Dwelling Unit Cooling Setpoint) 0.3
Example Corridor Corridor conditioned 21 °C, constant (Example Corridor Heating Setpoint) 24 °C, constant (Example Corridor Cooling Setpoint) 0.2
Example Stair Stair unconditioned none none 0.1

The stair is unconditioned as an illustrative choice, so that the conditioning rule of §1.2 is exercised by the pipeline's tests (for example, merging the stair with conditioned zones in S3). It says nothing about how any prototype conditions its stairs.

Preset Load type Basis Value Schedule
Dwelling unit Occupancy PerFloorArea 0.03 people/m² Example Dwelling Occupancy: weekday and weekend profiles below
Dwelling unit Lighting PerFloorArea 5.0 W/m² Example Dwelling Lighting: weekday and weekend profiles below
Dwelling unit ElectricEquipment PerFloorArea 5.0 W/m² Example Dwelling Equipment: constant 0.5
Corridor Lighting PerFloorArea 5.0 W/m² Example Always On: constant 1.0
Stair Lighting PerFloorArea 3.0 W/m² Example Always On: constant 1.0

No example preset defines GasEquipment, DomesticHotWater, or Ventilation, and the corridor and stair presets have no occupancy load. Since D-124 none has an infiltration load either: the three presets above carried 0.3 air changes per hour, always on, which now is the example envelope's infiltration (envelope presets).

The dwelling-unit profiles are fractions per hour of the day (hour 0 is the first hour of the day). The year starts on a Monday; Monday to Friday use the weekday profile, Saturday and Sunday the weekend profile.

Hour of day Occupancy, weekday Occupancy, weekend Lighting, weekday Lighting, weekend
0 1.0 1.0 0.1 0.1
1 1.0 1.0 0.1 0.1
2 1.0 1.0 0.1 0.1
3 1.0 1.0 0.1 0.1
4 1.0 1.0 0.1 0.1
5 1.0 1.0 0.2 0.1
6 0.8 1.0 0.4 0.2
7 0.5 1.0 0.4 0.3
8 0.3 0.8 0.2 0.4
9 0.2 0.7 0.1 0.3
10 0.2 0.6 0.1 0.2
11 0.2 0.6 0.1 0.2
12 0.3 0.6 0.1 0.2
13 0.2 0.6 0.1 0.2
14 0.2 0.6 0.1 0.2
15 0.3 0.7 0.1 0.2
16 0.5 0.8 0.2 0.3
17 0.7 0.9 0.5 0.5
18 0.9 0.9 0.8 0.8
19 0.9 1.0 0.9 0.9
20 1.0 1.0 0.9 0.9
21 1.0 1.0 0.7 0.7
22 1.0 1.0 0.4 0.4
23 1.0 1.0 0.2 0.2

2.2 Non-residential presets (S8.4)

The values below are illustrative, like those of §2.1: plausible round numbers for development and tests, NOT taken from the DOE prototype buildings, from any standard, or from measured data. Their reasons are recorded in ADR-014.

src/Lod.Core/Programs/ExampleNonResidentialPresets.cs defines one preset for each space type that the non-residential families place (D-094, D-097): the twelve new types and Core, Lobby, and Service. Each is available as PresetValues (OfficeValues, …, ServiceValues) and as the preset built from them (Office, …, Service); SpaceTypes, ValuesOf(SpaceType), and PresetOf(SpaceType) list and look them up. Every one is conditioned. The Grasshopper components Office Preset to Service Preset use these values as the defaults of their inputs (§5).

Preset (Name) Space type Heating Cooling WWR
Example Office Office 21 °C 24 °C 0.4
Example Core Core 21 °C 24 °C 0
Example Retail Retail 20 °C 24 °C 0.3
Example Mall Mall 20 °C 24 °C 0.2
Example Kitchen Kitchen 18 °C 26 °C 0.1
Example Dining Dining 21 °C 24 °C 0.4
Example Operating Theatre OperatingTheatre 20 °C 22 °C 0
Example Clean Corridor CleanCorridor 20 °C 24 °C 0.1
Example Dirty Corridor DirtyCorridor 20 °C 24 °C 0.1
Example Clinical Support ClinicalSupport 21 °C 24 °C 0.2
Example Care Bedroom CareBedroom 22 °C 25 °C 0.3
Example Care Communal CareCommunal 22 °C 25 °C 0.4
Example Lobby Lobby 20 °C 24 °C 0.5
Example Activity Hall ActivityHall 18 °C 25 °C 0.2
Example Service Service 18 °C 26 °C 0.1
Preset Load type Basis Value Schedule (annual sum of fractions)
Office Occupancy PerFloorArea 0.1 people/m² Example Office Occupancy (2231.55)
Office Lighting PerFloorArea 10 W/m² Example Office Lighting (2695.65)
Office ElectricEquipment PerFloorArea 10 W/m² Example Office Equipment (3526.8)
Core Lighting PerFloorArea 5 W/m² Example Office Lighting (2695.65)
Core ElectricEquipment PerFloorArea 3 W/m² Example Office Equipment (3526.8)
Retail Occupancy PerFloorArea 0.2 people/m² Example Retail Occupancy (2414.4)
Retail Lighting PerFloorArea 15 W/m² Example Retail Lighting (4547.5)
Retail ElectricEquipment PerFloorArea 5 W/m² Example Retail Equipment (5100)
Mall Occupancy PerFloorArea 0.1 people/m² Example Retail Occupancy (2414.4)
Mall Lighting PerFloorArea 10 W/m² Example Retail Lighting (4547.5)
Kitchen Occupancy PerFloorArea 0.05 people/m² Example Kitchen Staff (2244.6)
Kitchen Lighting PerFloorArea 12 W/m² Example Kitchen Hours (2610)
Kitchen ElectricEquipment PerFloorArea 30 W/m² Example Kitchen Electric (2952.6)
Kitchen GasEquipment PerFloorArea 40 W/m² Example Kitchen Gas (1122.3)
Kitchen Ventilation AirChangesPerHour 15 1/h Example Kitchen Hours (2610)
Dining Occupancy PerFloorArea 0.6 people/m² Example Dining Occupancy (809.1)
Dining Lighting PerFloorArea 10 W/m² Example Dining Hours (2349)
Dining ElectricEquipment PerFloorArea 2 W/m² Example Dining Hours (2349)
Operating Theatre Occupancy PerFloorArea 0.1 people/m² Example Theatre Sessions (2871)
Operating Theatre Lighting PerFloorArea 25 W/m² Example Theatre Services (4048.8)
Operating Theatre ElectricEquipment PerFloorArea 30 W/m² Example Theatre Services (4048.8)
Operating Theatre Ventilation AirChangesPerHour 20 1/h Example Theatre Ventilation (5946)
Clean Corridor Lighting PerFloorArea 8 W/m² Example Always On (8760)
Dirty Corridor Lighting PerFloorArea 8 W/m² Example Always On (8760)
Clinical Support Occupancy PerFloorArea 0.05 people/m² Example Theatre Sessions (2871)
Clinical Support Lighting PerFloorArea 12 W/m² Example Theatre Services (4048.8)
Clinical Support ElectricEquipment PerFloorArea 10 W/m² Example Theatre Services (4048.8)
Care Bedroom Occupancy PerFloorArea 0.04 people/m² Example Care Bedroom Occupancy (5803.5)
Care Bedroom Lighting PerFloorArea 6 W/m² Example Care Bedroom Lighting (2226.5)
Care Bedroom ElectricEquipment PerFloorArea 3 W/m² Example Care Bedroom Equipment (4380)
Care Communal Occupancy PerFloorArea 0.15 people/m² Example Care Communal Occupancy (3777.75)
Care Communal Lighting PerFloorArea 10 W/m² Example Care Communal Hours (6132)
Care Communal ElectricEquipment PerFloorArea 5 W/m² Example Care Communal Hours (6132)
Lobby Occupancy PerFloorArea 0.1 people/m² Example Community Occupancy (2444.5)
Lobby Lighting PerFloorArea 10 W/m² Example Community Hours (5267)
Activity Hall Occupancy PerFloorArea 0.1 people/m² Example Community Occupancy (2444.5)
Activity Hall Lighting PerFloorArea 12 W/m² Example Community Hours (5267)
Activity Hall ElectricEquipment PerFloorArea 2 W/m² Example Community Hours (5267)
Service Lighting PerFloorArea 6 W/m² Example Community Hours (5267)

Ventilation is given only for the kitchen (hood extract) and the operating theatre; no preset defines DomesticHotWater.

Dropped in D-124: the per-type infiltration rates. Until then every preset in the two tables above also had an Infiltration load in air changes per hour, always on (Example Always On): 0.8 for the mall, 0.6 for the lobby, 0.5 for retail, 0.1 for the operating theatre, and 0.3 for every other type. The mall, lobby, and retail rates stood for frequently opened entrance doors, and the operating theatre's for a pressurised suite (ADR-014). The rows are removed, not moved. A building now has one infiltration, a rate and a schedule on the envelope preset, the same for every zone, so these differences between space types are no longer represented; the values were illustrative (D-023), and a sourced value would set the building's infiltration, not a space type's. The year starts on a Monday. Monday to Friday use the weekday profile and Saturday and Sunday the weekend profile, except the three retail schedules, which have their own Saturday and Sunday profiles. Hourly fractions (hour 0 is the first hour of the day):

Office and core.

Hour of day Office Occupancy, weekday Office Lighting, weekday Office Equipment, weekday
0 0 0.05 0.2
1 0 0.05 0.2
2 0 0.05 0.2
3 0 0.05 0.2
4 0 0.05 0.2
5 0 0.05 0.2
6 0 0.05 0.2
7 0.1 0.3 0.4
8 0.5 0.8 0.7
9 0.95 0.9 0.9
10 0.95 0.9 0.9
11 0.95 0.9 0.9
12 0.5 0.8 0.7
13 0.95 0.9 0.9
14 0.95 0.9 0.9
15 0.95 0.9 0.9
16 0.95 0.9 0.9
17 0.5 0.6 0.6
18 0.2 0.3 0.4
19 0.1 0.2 0.3
20 0 0.05 0.2
21 0 0.05 0.2
22 0 0.05 0.2
23 0 0.05 0.2

Weekend: occupancy 0, lighting 0.05, equipment 0.2 all day.

Retail and mall (Saturday and Sunday differ).

Hour of day Retail Occupancy, weekday Saturday Sunday Retail Lighting, weekday and Saturday Sunday Retail Equipment, weekday and Saturday Sunday
0 0 0 0 0.1 0.1 0.3 0.3
1 0 0 0 0.1 0.1 0.3 0.3
2 0 0 0 0.1 0.1 0.3 0.3
3 0 0 0 0.1 0.1 0.3 0.3
4 0 0 0 0.1 0.1 0.3 0.3
5 0 0 0 0.1 0.1 0.3 0.3
6 0 0 0 0.1 0.1 0.3 0.3
7 0 0 0 0.1 0.1 0.3 0.3
8 0 0 0 0.5 0.1 0.6 0.3
9 0.3 0.5 0 1 0.1 0.9 0.3
10 0.5 0.8 0 1 0.5 0.9 0.6
11 0.6 1 0.4 1 1 0.9 0.9
12 0.8 1 0.6 1 1 0.9 0.9
13 0.8 1 0.7 1 1 0.9 0.9
14 0.6 1 0.7 1 1 0.9 0.9
15 0.6 1 0.6 1 1 0.9 0.9
16 0.7 0.9 0.4 1 1 0.9 0.9
17 0.8 0.8 0 1 0.5 0.9 0.6
18 0.7 0.6 0 1 0.1 0.9 0.3
19 0.4 0.3 0 1 0.1 0.9 0.3
20 0 0 0 0.5 0.1 0.6 0.3
21 0 0 0 0.1 0.1 0.3 0.3
22 0 0 0 0.1 0.1 0.3 0.3
23 0 0 0 0.1 0.1 0.3 0.3

Kitchen and dining (weekday; weekend: kitchen electric 0.2, every other schedule 0).

Hour of day Kitchen Staff Kitchen Hours Kitchen Electric Kitchen Gas Dining Occupancy Dining Hours
0 0 0 0.2 0 0 0
1 0 0 0.2 0 0 0
2 0 0 0.2 0 0 0
3 0 0 0.2 0 0 0
4 0 0 0.2 0 0 0
5 0 0 0.2 0 0 0
6 0.3 1 0.4 0 0 0
7 0.8 1 0.6 0.3 0.1 1
8 1 1 0.6 0.3 0.2 1
9 1 1 0.6 0.3 0.1 1
10 1 1 0.6 0.6 0.1 1
11 1 1 0.9 1 0.4 1
12 1 1 1 1 1 1
13 1 1 0.9 0.6 0.8 1
14 1 1 0.6 0.2 0.3 1
15 0.5 1 0.4 0 0.1 1
16 0 0 0.2 0 0 0
17 0 0 0.2 0 0 0
18 0 0 0.2 0 0 0
19 0 0 0.2 0 0 0
20 0 0 0.2 0 0 0
21 0 0 0.2 0 0 0
22 0 0 0.2 0 0 0
23 0 0 0.2 0 0 0

Operating suite (weekday; weekend: sessions 0, services 0.2, ventilation 0.5).

Hour of day Theatre Sessions Theatre Services Theatre Ventilation
0 0 0.2 0.5
1 0 0.2 0.5
2 0 0.2 0.5
3 0 0.2 0.5
4 0 0.2 0.5
5 0 0.2 0.5
6 0 0.2 0.5
7 0.5 0.6 1
8 1 1 1
9 1 1 1
10 1 1 1
11 1 1 1
12 1 1 1
13 1 1 1
14 1 1 1
15 1 1 1
16 1 1 1
17 1 1 1
18 0.5 0.6 1
19 0 0.2 0.5
20 0 0.2 0.5
21 0 0.2 0.5
22 0 0.2 0.5
23 0 0.2 0.5

Elder care (every day the same; Example Care Bedroom Equipment is constant 0.5).

Hour of day Care Bedroom Occupancy Care Bedroom Lighting Care Communal Occupancy Care Communal Hours
0 1 0.05 0.05 0.2
1 1 0.05 0.05 0.2
2 1 0.05 0.05 0.2
3 1 0.05 0.05 0.2
4 1 0.05 0.05 0.2
5 1 0.05 0.05 0.2
6 1 0.3 0.05 0.2
7 0.8 0.6 0.3 1
8 0.5 0.4 0.9 1
9 0.3 0.1 0.6 1
10 0.3 0.1 0.7 1
11 0.3 0.1 0.7 1
12 0.2 0.1 1 1
13 0.4 0.1 0.6 1
14 0.4 0.1 0.7 1
15 0.4 0.1 0.7 1
16 0.3 0.2 0.7 1
17 0.2 0.4 1 1
18 0.4 0.6 0.8 1
19 0.6 0.8 0.6 1
20 0.8 0.8 0.4 1
21 1 0.6 0.2 1
22 1 0.3 0.05 0.2
23 1 0.1 0.05 0.2

Community: foyer, activity hall, support rooms.

Hour of day Community Occupancy, weekday weekend Community Hours, weekday weekend
0 0 0 0 0
1 0 0 0 0
2 0 0 0 0
3 0 0 0 0
4 0 0 0 0
5 0 0 0 0
6 0 0 0 0
7 0 0 0 0
8 0 0 1 1
9 0.2 0.8 1 1
10 0.2 0.8 1 1
11 0.2 0.8 1 1
12 0.2 0.8 1 1
13 0.2 0.8 1 1
14 0.2 0.8 1 1
15 0.2 0.8 1 1
16 0.2 0.8 1 1
17 0.6 0.8 1 1
18 0.9 0.8 1 1
19 0.9 0.8 1 1
20 0.9 0.4 1 1
21 0.6 0 1 0
22 0.2 0 1 0
23 0 0 0 0

3. Sourced presets: an open research input

The v2 roadmap (§4, S1, slice feature/programs-presets) planned a DefaultResidentialPresets class "with DOE mid-rise apartment values as the starting point", with sources cited in this document. S1 deviates from that plan. It ships ExampleResidentialPresets with the illustrative values and conditioning choices of §2 instead, and the class name says so, so that no result can be mistaken for one based on prototype values. Roadmap v3 records sourced presets as open point 4 of its §7.

Sourcing preset values from the DOE mid-rise apartment prototype, with citations, is an open research input for the researcher: loads, schedules, and which spaces are conditioned. It does not block S2 to S4: their tests check geometry and conservation invariants, which hold for any valid preset values. When sourced presets are added, they must:

  1. cite, for every value and for each space type's conditioning status, the source document or model file, its version, and where in it the value is found (table, object, or field);
  2. state every conversion applied, including unit conversions to people, W, and m³/h, the mapping from the prototype's space types to BEMGen's SpaceType, and the mapping of the prototype's conditioning to conditioned or unconditioned (§4, item 1);
  3. be added alongside ExampleResidentialPresets (a new presets class, or presets built with the S2 components), leaving the example presets unchanged so existing tests keep their meaning;
  4. be recorded in the decision log (D-007) and in this document.

Since D-126 there is a second route to sourced values: a program JSON exported by the Energy Archetype Atlas gives a preset whose values, schedules, and provenance come from the atlas (§7). It does not replace the first: the atlas's JSON is read as published, with its checks, and BEMGen's own example presets stay illustrative.

4. Prototype assumptions deliberately not reproduced

Even with sourced values, BEMGen deliberately does not reproduce the following assumptions of a DOE prototype. Results must not be presented as if it did.

  1. Conditioning detail (D-038). A preset is either conditioned, with a heating setpoint schedule, a cooling setpoint schedule, or both (D-126), or unconditioned, with no setpoints. Any other conditioning arrangement a source describes must be mapped to one of these two, and the mapping stated (§3). HVAC systems themselves are not part of a preset (item 5).
  2. Zoning inside dwelling units (D-009). Rooms are never modelled. Z0 has at most one zone per dwelling unit; non-dwelling spaces are their own zones.
  3. Window layout (D-026, D-039). The S2 generator places one window centred on each outdoor wall, sized by the preset's WWR, not the prototype's window geometry.
  4. Calendar. Schedules are 8760 hourly values over a non-leap year (ADR-003). Schedules built from daily profiles use one weekday and one weekend profile, and holidays and special days are not modelled; only a program JSON is expanded on a calendar with holidays (D-126, §7), and the IDF holds the result as hourly values.
  5. Systems and envelope. A program preset holds loads (with their end uses, heat fractions, and hot-water temperatures), schedules, the occupants' heat properties, conditioning with setpoints, and WWR only: no HVAC system, construction, material, or infiltration data (infiltration is an envelope input since D-124). Constructions come from a separate envelope preset, the same at every level of detail (envelope presets, S6, ADR-010). The pipeline ends at Grasshopper-ready inputs without simulation (D-016); what the IDF export contains is decided in ADR-010 (S6).

5. Building custom presets

In C# (available from S1)

Every factory returns a Result<T>. Check IsSuccess and read Diagnostics before using a value built from unvalidated input: Value throws an InvalidOperationException that lists the errors. The numbers below are placeholders, like the example presets.

using System;
using System.Linq;
using Lod.Core.Common;
using Lod.Core.Loads;
using Lod.Core.Programs;
using Lod.Core.Schedules;
using Lod.Generators.Linear;

double[] weekday = Enumerable.Repeat(0.5, 24).ToArray();
double[] weekend = Enumerable.Repeat(0.8, 24).ToArray();
Schedule occupied = Schedule.FromDailyProfiles("My Occupancy", ScheduleKind.Fraction, weekday, weekend, DayOfWeek.Monday).Value;
Schedule alwaysOn = Schedule.Constant("My Always On", ScheduleKind.Fraction, 1.0).Value;

// A conditioned dwelling unit: its program has a thermostat.
Result<Thermostat> thermostat = Thermostat.Create(
    Schedule.Constant("My Heating Setpoint", ScheduleKind.Temperature, 20.0).Value,
    Schedule.Constant("My Cooling Setpoint", ScheduleKind.Temperature, 25.0).Value);

Result<ZoneProgram> unitProgram = ZoneProgram.Create(
    new[]
    {
        LoadDefinition.Create(LoadType.Occupancy, LoadBasis.PerFloorArea, 0.02, occupied).Value,
        LoadDefinition.Create(LoadType.Ventilation, LoadBasis.PerPerson, 30.0, occupied).Value,
        LoadDefinition.Create(LoadType.Lighting, LoadBasis.PerFloorArea, 4.0, alwaysOn).Value,
    },
    thermostat.Value);

// An unconditioned lobby: no thermostat, so no setpoints.
Result<ZoneProgram> lobbyProgram = ZoneProgram.Create(
    new[] { LoadDefinition.Create(LoadType.Lighting, LoadBasis.PerFloorArea, 3.0, alwaysOn).Value },
    null);

Result<ProgramPreset> unit = ProgramPreset.Create("My Dwelling Unit", SpaceType.DwellingUnit, unitProgram.Value, 0.25);
Result<ProgramPreset> lobby = ProgramPreset.Create("My Lobby", SpaceType.Lobby, lobbyProgram.Value, 0.4);

// From S4.1: change values of an example preset and build a preset from them.
Result<ProgramPreset> corridor = (ExampleResidentialPresets.CorridorValues with { Name = "My Corridor", WindowToWallRatio = 0.25 }).ToPreset();

// The linear plan generator takes one preset per space type (D-061).
var presets = new LinearPlanPresets(unit.Value, corridor.Value, ExampleResidentialPresets.Stair);

In Grasshopper (from S2)

S2 adds components that wrap the same factories: Schedule (an 8760-hour schedule from a 24-hour weekday and weekend profile), Load, and Program Preset (any space type, with a Conditioned input; a conditioned preset needs a heating or a cooling setpoint, or both, since D-126). Invalid inputs surface the diagnostics listed in §1 as component runtime messages.

S4.1 adds one default preset component per space type of the linear plan, Dwelling Unit Preset, Corridor Preset, and Stair Preset, and deletes Example Residential Presets (D-061). Every input of a default preset component has a default, the values of §2, so the component works with nothing connected: Name, WWR, Conditioned, Heating (°C), Cooling (°C), and per load a value input (people/m², W/m², or 1/h, as in its description) and an optional schedule input that replaces the built-in schedule when connected. Each shows the remark "Illustrative values; not sourced from DOE prototypes or standards." S8.4 adds one default preset component per non-residential space type of §2.2, Office Preset, Core Preset, Retail Preset, Mall Preset, Kitchen Preset, Dining Preset, Operating Theatre Preset, Clean Corridor Preset, Dirty Corridor Preset, Clinical Support Preset, Care Bedroom Preset, Care Communal Preset, Lobby Preset, Activity Hall Preset, and Service Preset, with the same inputs; Gas Equipment is in W/m², and Ventilation and Infiltration are in 1/h. Their inputs and outputs are listed in pipeline.md.

Since D-124 the default preset components have no Infiltration and Infiltration Schedule inputs, because their presets have no infiltration load. Mix Programs (panel 1 Program) mixes presets into one preset by weight (§6).

D-126 appends inputs and outputs, so definitions saved with 1.1.0 open unchanged. Load gains End Use; Radiant, Latent, Lost, Visible, and Return Air (lighting and equipment only); and Target Temperature and Inlet Temperature (hot water only); its Basis offers PerDwellingUnit. Schedule's Kind offers Activity. Program Preset gains Heating On, Cooling On (a side is on when Conditioned and its switch are true and its setpoint is connected), Activity, People Radiant, and People Sensible. Each default preset component gains Heating On and Cooling On, after its load inputs; its loads take the default end uses, heat fractions, and water temperatures. The new component Program JSON is described in §7. The inputs and outputs are listed in pipeline.md.

S8.8 moves the eighteen default preset components to their own panel, 1 Program Presets; Schedule, Load, and Program Preset stay in 1 Program, with the new parameter Any Program Preset (AnyP, D-108). Wire any preset into Any Program Preset and its output into any preset input of any generator to apply that program to the input's space type: for example an Office Preset through Any Program Preset into the Corridor input of the Linear Plan Generator gives the corridor the office program while it stays a Corridor zone. The preset keeps its name, loads, schedules, conditioning, setpoints, and WWR, and the plan's provenance records the use.

6. Mixed presets (D-124)

Mix Programs (ProgramMix.Mix in Lod.Core.Programs, ADR-017) mixes one or several program presets into a new preset by a weight per input: the program of a space made of, say, 70 % office and 30 % retail floor area. It works on any preset, an example, a sourced one, a default preset component's, an any-program preset, or a mix.

6.1 Inputs and checks

  • Weights are floor-area shares: "think of the weight as area". One weight per preset, in the same order, each finite and greater than 0 (MixWeight; zero is an error because a preset without a share does not belong in the mix, and its absolute loads would otherwise be added silently); a count other than the preset count is MixWeight too. They are normalised to sum to 1 (ŵᵢ), so only their ratio matters.
  • Name is optional. When it is missing it is Mix of A 0.7, B 0.3: each input's name and normalised weight to three significant digits.
  • Space type is optional. When it is missing, the mix takes the space type of the input with the largest weight, the first such input in list order on a tie; an any-program input chosen so makes an any-program mix. The provenance records the choice.
  • WWR is optional. When it is missing, the mix takes the weighted mean Σ ŵᵢ·WWRᵢ, glazing per wall shared like floor area, and records it as derived. A given WWR must lie in [0, 1) (WindowToWallRatio).
  • Conditioning. Mixing conditioned with unconditioned inputs is allowed, as in zone merges; the info MixedConditioning names the unconditioned inputs and the share that becomes conditioned.
  • A per-person load beside absolute occupancy is an error (PerPersonWithAbsoluteOccupancy) when they are in any of the inputs, one input or two. A mixed per-person value is weighted by the occupants per m² each input brings, and absolute occupants per m² depend on a zone area a mix does not know; at unit area an input's absolute occupancy would dilute another input's per-person load (a hall of 5 people mixed half and half with an office of 0.1 people/m² at 30 m³/h per person would give 2.97 m³/h on a 100 m² zone, where merged zones of 50 and 50 m² give 150 m³/h). Express the occupancy per floor area. Absolute occupancy is fine when no input has a per-person load.
  • Occupancy in several bases is an error with a per-person load or different people properties (MixedOccupancyBases, D-126). The virtual zone of a mix has unit floor area and one dwelling, so occupants per m², per dwelling, and absolute would be added as if they were one quantity, and the per-person values and the people properties would be weighted by a wrong split (0.05 person/m² at 10 m³/h per person mixed half and half with 3 person/dwelling at 30 m³/h per person would give 29.67 m³/h per person). A mix with one occupancy basis, or with identical people properties in the inputs with occupants and no per-person load, stays allowed. Express all occupancy in one basis.

6.2 The rule

The mix is the zone merge of ADR-007 and ADR-005 applied to one virtual zone of floor area 1 and volume 1 whose sources are the inputs: input i is a source of floor area and volume ŵᵢ (one common height), transferred whole, so every basis follows the rule zone merges already use.

Component Mixed value Mixed fraction schedule
Per floor area (lighting, equipment, occupancy, ventilation, hot water, …) Σ ŵᵢ·vᵢ; a preset without the component contributes 0 Σ ŵᵢ·vᵢ·sᵢ(t) / Σ ŵᵢ·vᵢ
Air changes per hour Σ ŵᵢ·vᵢ the same form
Per dwelling unit (D-126) Σ ŵᵢ·vᵢ: each weight stands for the input's share of dwellings, as it stands for its share of floor area the same form
Heat fractions of a lighting or equipment component (D-126) each fraction weighted by the transferred magnitude —
Activity of people (D-126) weighted every hour by the transferred scheduled occupants —
Radiant and sensible fraction of people (D-126) weighted by the occupants each input brings; a mixture of a number and autocalculate gives autocalculate and a warning —
Hot-water target and inlet temperatures (D-126) each weighted every hour by the transferred scheduled flow; inputs all on the weather file's mains stay on the mains, and mains mixed with inlet schedules are an error (WaterInletMixed, D-172) —
Daylighting controls (D-172) the controlled fraction weighted by the lighting power each input transfers, an input without controls counting with 0, so the controlled lighting power is conserved; the settings of the input controlling the most power, with the warning DaylightingSettingsDiffer when they differ —
Per person (ventilation per person, …) Σ ŵᵢ·oᵢ·vᵢ / Σ ŵᵢ·oᵢ, weighted by the occupants per m² (oᵢ) each input brings Σ ŵᵢ·oᵢ·vᵢ·sᵢ(t) / Σ ŵᵢ·oᵢ·vᵢ
Absolute (a fixture's flow, …) Σ vᵢ, raw, not weighted Σ vᵢ·sᵢ(t) / Σ vᵢ
Conditioning conditioned when any input is —
Heating setpoint Σ ŵᵢ·θᵢ(t) / Σ ŵᵢ over the inputs that heat only, renormalised over them; heating is on when any input heats (D-126) —
Cooling setpoint the same over the inputs that cool —

Each component keeps its basis and its end use: different bases or end uses of one load type stay side by side and add up at export (D-047, D-126). A mix of presets expanded on different calendars is an error (CalendarMismatch); the mix carries the calendar the inputs share. Crossed heating and cooling setpoints after a mix are an error, as after a zone merge. A merged magnitude of zero gives value 0, a constant-zero schedule, and the info ZeroLoadSchedule. Absolute values are added raw whatever the weights (the owner's rule: fixed values are "just there"), so a mix of one preset is that preset and a mix of a preset with itself doubles its absolute loads. Setpoints are a prescribed control rule, not a conservation invariant (ADR-005); the caveat that chained mixes renormalise their conditioned inputs step by step, so a mix of mixes can differ from the one-step mix, is accepted (ADR-017).

Example: A (lighting 10 W/m², occupancy 0.1 people/m², ventilation 30 m³/h per person, hot water 0.5 m³/h absolute) and B (4 W/m², 0.02 people/m², 10 m³/h per person, 0.2 m³/h) with weights 7 and 3 give lighting 8.2 W/m², occupancy 0.076 people/m², ventilation (0.07·30 + 0.006·10) / 0.076 = 28.42 m³/h per person, and hot water 0.7 m³/h.

6.3 Equivalence with zone merges

A plan of two zones of 70 m² and 30 m² with the presets A and B, merged into one zone by Single Zone per Floor, has the same densities, per-person and air-change values, schedules at every hour, and setpoints at every hour as Mix Programs with weights 0.7 and 0.3 (ProgramMixEquivalenceTests). In general a mix equals the merge of zones whose floor areas are in the ratio of the weights, for per-floor-area, air-change, and per-person components, schedules, conditioning, and setpoints, when occupancy is per floor area. The two differ only where a zone merge has more information than a mix:

  • A merge weights air changes by volume and a mix by floor area; they agree because a mix has one common height.
  • Absolute loads agree when each input stands for one source zone, transferred whole: each is added raw in both. A preset used by k zones of a plan has its absolute value added k times by a merge, and once by a mix. A source zone split between targets by a rezoning transfers only its fraction of an absolute value, which a mix has no analogue for.
  • Absolute occupancy beside a per-person load has no equivalent in a mix, which is why a mix rejects it (§6.1).

This equivalence is a unit test, not a runtime check: a mix has no source plan to validate against. What the user should expect from a mix is therefore what a zone merge of the same shares would give, with the weights as areas.

6.4 Provenance

The mix is a ProgramPreset whose Source is Provenance.Of("MixPrograms", …): one parameter Input.k per input holding the preset's name, the given weight, and the normalised weight (the source and weight pairs), the SpaceType and WindowToWallRatio with how each was chosen (given, largest weight, Input.k, or weighted mean), and each input's own Source as an input, so a mix of program JSON presets traces to their JSON records and a mix of mixes nests. Every mixed load and schedule has an AggregationRecord whose sources are the keys Input.k, not the preset names, which may repeat. A plan made from a mix records the source among its provenance inputs, and Inspect prints it.

7. Atlas programs: program JSON (D-126)

Since D-239 (version 1.9.0) it reads program JSON 6.0.0 of atlas release 2.3.0 only, which adds evidence rows of one shape, a status beside every load value, and a dwelling's window ratios by its context (ADR-038); what follows holds for it.

Since D-172 the component reads program JSON 5.4.0 of atlas release 2.0.0 in its source and filled versions, not 2.0.0. What changes for the preset: the values are resolved for the Climate Zone and Context inputs; a source version's unrecorded values are left out or take BEMGen's defaults with warnings; the JSON's fenestration gives the glazing when the inputs do not; the program carries the source model's daylighting controls as plain values, applied as given and never recomputed from BEMGen's geometry (atlas decision L-1; the rule of a merge is in §6.2, the same rule as a zone merge); and the hot water of the filled version takes the weather file's water mains as its inlet. The bullets below describe D-126 and hold otherwise; program-json.md has the 5.4.0 contract.

Daylighting in a merge (D-172). The aggregation rule is a conservation rule, like the loads': the controlled lighting power Σ cᵢ·Pᵢ of the sources (cᵢ the controlled fraction, Pᵢ the transferred lighting design power of all lighting end uses) is the target's, so the merged fraction is Σ cᵢ·Pᵢ / Σ Pᵢ, a source without controls contributing cᵢ = 0. The other settings are controls, not quantities, and are not averaged: the target takes those of the source with the largest cᵢ·Pᵢ (the atlas's own rule for a program, "the settings of the zone with the most lighting power"), and differing settings are a warning. The merged zone has one reference point controlling that fraction of its lights, so the share of lighting power under daylight control is the same in the source and the target; the daylight that reaches the reference point depends on the target's windows. Written to an IDF, that would make the realized lighting energy differ between a zoning and its reference, so the pairing check of the evaluation metrics (D-157), which requires hourly lighting conserved, would fail. Decided (D-174, 2026-10-29): the owner said "let's not include dimming for our idf runs ever"; daylight dimming is held fixed as part of the lighting load, never measured as a geometry effect (GLOBAL.md scientific rules 1 and 4), and Convert2IDF never writes the controls. The merge rule still keeps the controls conserved on the programs, as source data and provenance. Amended (D-233, ADR-037, 2026-11-01): D-174's rule is the default; with Convert2IDF's Daylighting option on, the merged zone's controls are placed by the 90.1 code rule on its own windows and skylights, with the settings (and the code rule, part of them) of its lead source; the conserved fraction stays provenance, not what is written.

A preset can come from the Energy Archetype Atlas instead of from typed values: the Program JSON component (panel 1 Program, nickname PJson) turns the text of a program JSON 2.0.0 into a program preset. The contract, the mapping, the checks, and the overrides are in program-json.md; this section says what the preset is.

  • What the JSON gives. The loads of the program (occupancy, lighting, electric and gas equipment, hot water) with their end uses, bases, and heat fractions; every schedule they use, expanded to 8760 hourly values on the calendar of the Year (default 2007) and Holidays inputs; the heating and cooling switches and setpoint schedules; the occupants' activity schedule and radiant and sensible fractions; and the hot-water target and inlet temperature schedules. Only the defaulted export is read: the atlas has already replaced unknown values under its policy atlas-program-defaults-1.0.0, and the component lists each substitution it recorded in its Assumptions output.
  • What it does not give. A window-to-wall ratio (the WWR input, an illustrative 0.4 unless set, not from the JSON), a space type (unset: an any-program preset, §5), and any load the contract lacks, such as ventilation (the Loads input). Shared services are left out and listed.
  • Whose values. The values are the atlas's, not BEMGen's illustrative ones, and they stay the atlas's: BEMGen changes none of them except the unit of a hot-water flow (m³/s to m³/h). Overrides are explicit inputs and are recorded.
  • Provenance. The preset's Source records the JSON's id, name, scope, mode, and SHA-256 (of its canonical JSON since D-226, the atlas site's json_sha256; of the text with LF line endings before, D-128), the store file it was taken from on the atlas site (Json.Store), the source program (id, release, building type, template, evidence view), the default policy and the number of its substitutions, the calendar, the window-to-wall ratio and the space type with how each was chosen, every override, the demands that were combined, and the shared services left out. The JSON's assumptions and evidence are not copied into every schedule.
  • Use. The preset is an ordinary ProgramPreset: it goes into any preset input of a plan generator, into Any Program Preset, or into Mix Programs. It carries its calendar, so it can only be combined with programs on the same calendar (§1.3), and its per-dwelling loads (if any) need dwelling-unit zones.