Constructions, native ground, and ground heat transfer in test suites and the batch runner (design note)

Status: Done on feature/test-suite-generator (built, reviewed, verified, D-151); merged into main (D-152) and pushed (D-154); released in v1.5.0 (D-175) · Date: 2026-10-19 · Decisions: D-133 to D-136, D-137 to D-150 (on main); new: D-151 · Branch: feature/test-suite-generator, on main 3da0bba (packet v7 and native ground merged, D-150; D-136: work continues here)

This is one stage, run as D-111 sets out:

  • this note;
  • one test-first build;
  • a review by a second agent;
  • scripts/verify.ps1 before the merge;
  • one decision-log entry.

It makes no Grasshopper component changes. Program JSON 3.0.0 is the next stage, with its own note (Programs). The schedule generator is not part of either.

Stop line. The build ends with the branch verified, reviewed, and documented. It does not merge, tag, push, or release.

What changed since the test suites (review)

Constructions (D-137 to D-144, v1.4.0)

  • Import. Construction JSON imports the atlas's construction JSON into a ConstructionSet (Lod.ConstructionJson, Lod.Core.Envelope).
  • Conversion. Convert2IDF takes the set through Convert2Idf.Run(building, ConstructionSet, IdfOptions, …), with IdfOptions.FillFromExample.
  • Scope. Only unified sets of scope building convert. Single-dwelling sets and detailed documents are refused (D-142).
  • Fill From Example (default false) fills a role the set marks not applicable with the Example envelope's construction, with a warning. Without it, a missing role is the error ConstructionMissing (D-140).
  • Mass. A set adds mass from its reference budgets (the mass ledger, D-139). A slab removed by a merge is written as twice its area at half its thickness, so its capacity counts once (D-143). The ledger holds on every zoning.
  • Windows. A set's windows take its incident solar multiplier, which was checked in EnergyPlus (D-143).

Ground conditions (D-145 to D-149, merged as D-150)

  • Packet. Packet v7 replaces v3, with readers for unified 2.0.0 and detailed 3.0.0. The v3 readers are retired (D-145, D-146, ADR-023).
  • Native ground. A v7 set's ground floor takes the set's own GroundFloor method:
  • F-factor: Construction:FfactorGroundFloor with the set's F, the piece's area, and its exposed perimeter, with shared zone edges cancelled. A core's perimeter is exactly 0 (D-149).
  • Layered ground: the set's layers on Ground.
  • Ground temperatures follow the source's rules:
  • F- and C-factor surfaces: the weather file's monthly mean dry-bulb, delayed three months and rounded to 0.1 °C. A v7 set with such surfaces and no weather file is refused.
  • Layered ground: BuildingSurface at 18 °C in every month.
  • Without a set: D-130's rule stays.
  • Diagnostics:
  • GroundMethodNotSupported, GroundTemperatureWeatherMissing, and GroundAssignmentSetAside.
  • ExampleWindowSolarNotAbsorbed (D-147) warns when Example windows fill a set without windows over a ground floor that absorbs no solar. EnergyPlus then reports one severe error per such zone.
  • Checked in EnergyPlus 26.2. These cases passed with no unexpected warning:
  • the office, warehouse, apartment, and tall-building F-factor cases;
  • the layered hospital cases;
  • the turned plans with courts, now that core perimeters are exactly 0 (D-148, D-149).

The runner's list of expected warnings is unchanged. - Open (ADR-023): - the crawlspace or garage air exchange is unsupported; - the C-factor soil resistance appears capped; - the schemas' $id versions differ from the documents', to be reported to the atlas.

Why constructions and ground fit a test case

A test site may differ from its reference only in zoning (D-133). The changes keep that:

  • The mass ledger and the half-thickness slices conserve heat capacity across zonings (D-143).
  • The F-factor perimeters times multipliers keep the footprint's perimeter on every zoning (D-146, D-149).
  • The ground temperatures depend only on the weather file and the set, both fixed per test case.

So a construction set, its fill choice, and its ground method are test-case inputs. Their effects across a test case's sites are zoning effects.

Programs

Nothing changed in BEMGen since Program JSON 2.0.0 (D-126, v1.2.0). The atlas (branch codex/foundation-ground, e9a982d, read only) now has two newer contracts.

Program JSON 3.0.0 is the form the catalogue exports. It changes the physical model, not only the file format:

  • object-specific heat fractions (lights: radiant, visible, return air; equipment: radiant, latent, lost);
  • explicit conditioning states, with no setpoint for a disabled service;
  • zero loads omitted;
  • fuel and host kept, so propane is not natural gas and may need OtherEquipment;
  • exterior lighting;
  • shared services instantiated once;
  • hot-water mains from EnergyPlus's weather-file correlation instead of a fixed 10 °C;
  • metadata.resolutions replaces assumptions.

So it needs changes to the program model in Lod.Core, to Lod.ProgramJson, and to Convert2IDF's loads. It is a stage of its own, not part of this one.

Program JSON 4.0.0 is opt-in. It moves hot water out of loads into water_heating draws on heaters with a fuel and a conversion efficiency. That changes how the experiment outputs count hot water: today it is district heating water (experiment outputs §1). So it is a research change, left for a later decision.

Files for the 3.0.0 stage. The 3.0.0 stage copies these from the atlas at e9a982d into its test fixtures and schemas (the owner's allowance, 2026-10-19). The table gives the first 16 hex digits of each file's SHA-256:

File Bytes SHA-256
schemas/program-json-v3.schema.json 41 329 9647eb7bd5ee0f12…
schemas/schedule-json-v2.schema.json 8 401 ea61c7bdf58e19ca…
docs/examples/program-json-v3/medium-office.defaulted.json 55 029 2ffc1bd338cd59e2…
docs/examples/program-json-v3/medium-office.raw.json (a raw file, to be refused) 45 251 7f3b08875a3f98c8…
docs/examples/program-json-v3/residential.defaulted.json 2 886 769 74437bb92ccd2248…

The residential example is large. Its stage decides whether to commit it, or to keep it outside the repository behind an opt-in test.

Once Program JSON reads 3.0.0, the suite generator needs no change of its own: program_json takes whatever the importer accepts, and a program's content is already hashed into the test case ID.

Plan

Part A: the test-suite generator

  1. Spec, still version 1 (an additive change). A constructions entry gives either builtin: Example (as now) or a unified construction JSON:
constructions:
  example: {builtin: Example}
  office-5a: {construction_json: constructions/medium-office-2019-5A.unified.json, labels: {vintage: "2019"}}
  office-4b: {construction_json: https://…/medium-office-2019-4B.unified.json, sha256: 1f2e…, fill_from_example: true}
  • construction_json is a file next to the spec, or a URL pinned by sha256, as programs are.
  • fill_from_example defaults to false.
  • Inputs. A ConstructionFiles class, alongside ProgramFiles:
  • each file is located and hashed when the plan is made;
  • with --write, it is fetched and imported (ConstructionJsonImporter.Import) before anything is written;
  • each file is kept in inputs/ by its SHA-256.

A refused set stops the suite with exit code 2, before the suite folder exists. Refusal covers: - a scope other than building; - a schema or closure error; - an F- or C-factor set in a suite that has no weather file for it. 3. Test case ID. The constructions part holds the content, not the id: builtin:Example, or json:<sha256>;fill=<bool>. Two entries with one file and one fill choice are the same inputs, which is an error as today. 4. Pairing by climate (the owner, 2026-10-19). A construction set and its ground are made for one climate, so the generator pairs each set only with weather files of the set's climate zone (ConstructionJsonImport.ClimateZone): - The cross product of constructions and weather files keeps only the matching pairs. A non-matching pair is never a test case, so it is not listed as excluded either. - builtin: Example has no climate zone and pairs with every weather file, as now. - A set whose zone matches no selected weather file is an error in the plan, since the spec would write nothing for it. - Programs keep their existing climate filter (ExcludedByClimate). - The plan's printout gives the pairs per set. 5. Writing. Convert2Idf.Run(building, set, new IdfOptions(heat) { FillFromExample = … }, file, weather). - The conversion's warnings are kept per site in a new suite_sites.warnings column. - Invalid sites (the owner, 2026-10-19). A site whose conversion gives ExampleWindowSolarNotAbsorbed is Invalid and is not written, because EnergyPlus would fail it with severe errors. Its row records the diagnostic. - If the reference is such a site, its test case is ReferenceInvalid, as today. 6. Tables. test_cases gains five columns, and the same values go into test_case_parameters: - constructions_kind: builtin or json; - constructions_sha256; - constructions_climate_zone; - fill_from_example; - ground_method, one of: - IndoorMinus2: no set (D-130); - FFactor or Layered: a v7 set (D-145); - (no Mixed: see the build log) 7. Tests, first. These use the pinned packet v7's fixtures (tests/Lod.ConstructionJson.Tests/Fixtures/packet/). - Spec: - a URL without sha256; - an unknown key; - fill_from_example that is not a boolean. - Plan: - IDs by content; - pairing: the 3B medium office set with a 3B and a 5A weather file gives one pair, and builtin: Example gives two; - a set with no matching weather file is an error. - Writing: - The medium office F-factor set on the linear plan. Every site is written with F-factor ground, and every site's Σ P × multiplier equals the footprint's perimeter. - A layered set: BuildingSurface at 18 °C. - A single-dwelling set: refused before writing. - The small data centre's windowless set with fill, on a windowed plan: Invalid, with the warning, and no file.

Part B: ground heat transfer (the owner, 2026-10-19)

A new building-level raw output: the hourly heat that ground-contact surfaces conduct into the zones. Like the temperatures (experiment outputs §5), it is a building-level sum, never compared zone by zone. A research addition, so it changes docs/research/experiment-outputs.md in the same change (GLOBAL.md scientific rule 7).

  1. Definition. For hour t, G(t) = Σ_s m_z(s) · Q_s(t), over every heat-transfer surface s whose outside boundary condition is Ground, GroundFCfactorMethod, or OtherSideCoefficients used for ground. In this definition:
  2. m_z(s) is the multiplier of the surface's zone;
  3. Q_s(t) is EnergyPlus's Surface Inside Face Conduction Heat Transfer Energy for s.

Its unit is W, as an hourly mean, like the load series. Its sign is EnergyPlus's: positive when heat enters the zone through the inside face. The build confirms the sign on a run before writing it down.

Not included: - a surface paired with another zone (Surface); - an adiabatic surface; - an outdoor surface. 2. The IDF (Lod.Export). The research output set requests: - Surface Inside Face Conduction Heat Transfer Energy, hourly, keyed by the name of each ground-contact surface. Keying by name, not *, keeps the .eso small; - Output:Surfaces:List, Details, so that eplusout.eio lists every surface with its zone and its outside boundary condition.

Every building has ground-contact surfaces (ADR-010), so the requests are unconditional. The snapshots and docs/architecture/convert2idf.md change. 3. Reading (Lod.Simulation). - SimulationResultReader reads the surfaces' zones and boundary conditions from the .eio, never from the IDF. The zone multipliers already come from there (§5). - It sums the variable into SimulationResult.GroundHeatTransfer, an HourlySeries. - A run without the variable fails with the reader's actionable error, as a missing meter's would. - A building whose .eio lists no ground surface has a zero series. 4. Metrics. The annual net, the annual gain (the sum over hours with G > 0), and the annual loss (the sum of −G over hours with G < 0), in kWh. There is no comparison with the reference yet; the comparison metrics of §4 stay on the loads. 5. The runner. - Batch database: a new series GroundHeatTransfer, of kind Ground, in the long table. - Central database: a new table hourly_ground (site_key, hour, value_w), with its long view, and merges that copy it. - Site columns: annual_kwh_ground_net, annual_kwh_ground_gain, and annual_kwh_ground_loss. - The central database's schema_version goes up by one. A merge refuses databases of different versions with a message, as it refuses other mismatches. 6. Tests, first. - Lod.Export: the output requests on the snapshots, keyed by ground surface; a building with a multiplied ground floor. - Lod.Simulation: - the reader on small .eio and .eso fixtures: two ground surfaces in zones with multipliers 1 and 3, one paired floor left out, and the sum and sign; - a zero-ground building; - the missing variable; - the annual metrics with the zero cases. - Runner: - the scripted EnergyPlus writes the variable, and the series, table, and columns follow; - a merge across schema versions is refused. - Opt-in EnergyPlus run: the medium office F-factor set on a two-storey linear plan. The variable is present; G is negative in winter; and the .eio's ground surfaces are exactly the IDF's.

Part C: the batch runner, suites with constructions

  1. No change to the site record. The IDF header's ! Site envelope: line already names the set. A suite's constructions and ground method reach central.duckdb through the copied test_cases table, and site_results gains constructions_kind, constructions_sha256, ground_method, and fill_from_example. A plain IDF run (not a suite) keeps the envelope name only.
  2. Expected warnings. None are added in advance. The pilot below runs every v7 ground method through scripts/eplus-check and the runner. Any new warning is added only with its reason and a decision (scripts/eplus-check/README.md).
  3. Tests.
  4. A suite with a construction set, run on the scripted EnergyPlus: site_results carries the new columns. A merge with a builtin-only suite keeps the builtin rows with constructions_kind = builtin.
  5. Opt-in: a suite of the packet's medium office F-factor set (3B) and the warehouse set (3B), on a 3B weather file, through the runner on EnergyPlus 26.2:

    • every site succeeds;
    • the reference's comparison metrics are 0;
    • each test site's annual loads and annual ground heat transfer are reported against its reference.

    The weather file is the one the owner named on 2026-10-19: OpenEPW Las Vegas, Nevada (NSRDB GOES TMY v4.0.0, TMY 2025, climate zone 3B; SHA-256 b94c04eeedd357a8…), kept outside the repository. The test reads its path from BEMGEN_WEATHER_3B and is skipped without it, as without EnergyPlus.

Part D: documentation

  • The generator's and runner's READMEs, and the spec schema.
  • docs/research/experiment-outputs.md (§1 or a new section for ground heat transfer, §8, and "What the IDF requests"), and docs/architecture/convert2idf.md.
  • AGENTS.md's commands, ADR-020's consequences, and D-151.

Construction files for suites

Packet v7's examples are mostly 3B, with residential sets in 1A, 4A, and 5A. A pilot in other climates needs construction JSON for its climate zones. The atlas's combined construction release 1.0.0 (data/construction-foundation-releases/v1.0.0, 177 suites and 3320 contexts) is internal storage. Its README says standalone documents come from its exporter: --context-id ID --representation unified --output PATH.

So:

  • Fetching. The pilot's sets are exported by the owner, or by the build with the owner's yes. The export is written outside both repositories and modifies nothing in the atlas.
  • Storage. The files sit next to the pilot spec, outside the repository, as the program files do. They are never committed (the packet's licence note).
  • Tests. The repository's tests use only the pinned packet v7 fixtures.

Order

  1. Parts A and B, test-first, in parallel worktrees: A touches only scripts/TestSuiteGenerator, and B touches Lod.Export, Lod.Simulation, and the runner's series.
  2. Part C, after both.
  3. Review, scripts/verify.ps1, the opt-in EnergyPlus runs, Part D, and D-151.
  4. Next stage: Program JSON 3.0.0, with its own note.

Decided with the owner (2026-10-19)

  1. Base. Packet v7 is merged into main (D-150). This stage builds on it.
  2. Pairing. The generator pairs each construction set with the weather files of its climate zone. Climate must match the construction and its ground by design.
  3. Example windows over a non-absorbing ground floor. The site is Invalid and not written.
  4. Programs. The 3.0.0 files come from the atlas's codex/foundation-ground branch at e9a982d, read only.
  5. Ground output. Add the hourly building-level ground heat transfer (Part B).
  6. Cleanup. The v7 sibling branches are deleted and their worktrees deregistered.

Build log (2026-10-19)

Parts A and B were built in parallel worktrees (feature/suite-constructions, feature/ground-heat-transfer) and merged into feature/test-suite-generator; Part C followed there.

Deviations from the plan above, each with its reason:

  • Construction URLs are fetched when the plan is made, not only with --write: pairing needs the set's climate zone, which is inside the file. Program URLs still download only with --write.
  • Two more refusals before writing. A set whose ground floor cannot be placed (GroundMethodNotSupported, ConstructionBlocked, or an uncovered ground without fill) is refused, since every building has ground floors (ADR-010) and every site would fail. A detailed document is refused (D-142).
  • The F/C-factor weather refusal is per paired weather file without a full year of hourly records; a suite always has weather files.
  • ground_method has no Mixed. The converter resolves one building-default ground recipe for a set and sets any other rule aside with GroundAssignmentSetAside, so no set gives more than one method.
  • Ground heat transfer counts Ground and GroundFCfactorMethod only (FCGround in the .eio). OtherSideCoefficients is not counted: the .eio names only the coefficients object, so the reader cannot tell a ground use, and BEMGen writes none.
  • No export test with a multiplied ground floor: the pipeline always splits the ground storey off at multiplier 1 (D-046). The multiplier is tested in the reader instead (zones with multipliers 1 and 3).
  • The research addition is experiment outputs §9, not a section after §5, so that the many references to §6 to §8 stay valid.
  • The sign, confirmed in the EnergyPlus 26.2 I/O reference and on runs: positive is heat conducted toward the zone through the inside face, negative heat leaving it. EnergyPlus does not apply the zone multiplier to surface outputs, so the reader does.

Checks:

  • scripts/verify.ps1 on each part's branch: VERIFY PASSED, 0 warnings.
  • Part B's opt-in run (the medium office F-factor set, two storeys, the owner's Las Vegas file): 0 warnings, 0 severe; the .eio's 6 ground surfaces equal the IDF's; annual G net −3715.2, gain 2946.9, loss 6662.1 kWh. scripts/eplus-check on that IDF: PASS, no new warning from the output requests.
  • Part C's opt-in pilot (the F-factor medium office and warehouse sets, 3B, on the linear plan with storeys [1, 2, 1], 2 test cases of 8 sites, the owner's Las Vegas file): all 16 sites succeeded, each reference's comparison metrics 0. Example rows (annual total, change against the reference, ground net, in kWh):
Site Total Δ total Ground net
Office reference 249 806 0 −3 935
Office, Perimeter Core + Stack, IWHT/FHT off 261 508 +11 702 −3 762
Office, Perimeter Core + Single Zone Building (either heat-transfer setting) 247 452 −2 354 −4 478
Warehouse reference 256 811 0 −4 140
Warehouse, Perimeter Core + Stack, IWHT/FHT off 274 451 +17 640 −3 929

These come from one synthetic plan and one weather file; they test the pipeline, and are not experiment results. - A full opt-in Lod.Simulation.Tests run with a long output path failed two turned-court cases because EnergyPlus wrote no eplusout.err; with a short BEMGEN_SIM_OUT all four passed. Keep BEMGEN_SIM_OUT short on Windows.